Re: Max routing context value.

Ankit Kumar Sharma <[email protected]> Thu, 3 Mar 2011 01:13:23 +0530
Newsgroups gmane.ietf.sigtran
Message-ID <[email protected]>
Yes, you should be able to configure a value in between 0-4294967295. It
seems your stack has set the upper limit to 2 bytes (unsigned) for the
routing context value.

On Thu, Mar 3, 2011 at 12:27 AM, Kulkarni, Vijay K. (NSN - IN/Bangalore) <
[email protected]> wrote:

>  Hi,
>     we have issue with routing context, where we want to configure routing
> context value higher than 65535.
>     but configuration is failing, as stack accepts only* unsigned int* (0
> - 65535).
>
>     And from RFC its clear that its 4 octet value. So cant we give the
> value more than 65535?
>
> -vijay.
>
> _______________________________________________
> Sigtran mailing list
> [email protected]
> https://www.ietf.org/mailman/listinfo/sigtran
>
>

_______________________________________________
Sigtran mailing list
[email protected]
https://www.ietf.org/mailman/listinfo/sigtran