Re: [MTP3] Change Over procedure for 2M TDM links
arif khan <[email protected]> Tue, 5 Apr 2011 15:27:56 +0100
| Newsgroups | gmane.ietf.sigtran |
|---|---|
| Message-ID | <[email protected]> |
Yes ....It is possible with broadband support at the SCCP and MTP3 Level for HSL Regards -arif On 4/5/11, Santhana <[email protected]> wrote: > Hi > > I am not sure whether I can send queries regarding MTP3 in this WG. If > I am wrong pls suggest the group from which I can get the below MTP3 query > clarified. > > > > My Query: > > Can MTP2 be run on 1.5/2M links ? > > > > In Q.703 it is explained that for the ChangeOver procedures of 2M > links extended sequence number may be used for FSN/BSN transporting. It is > also mentioned that the extended sequence numbers should be of 12 bits in > this case. > > In the Note(6) page no 82, it refers to Q.2210(MTP3B) specification. > > > > Does this mean that for 2M MTP2 links XCO/XCA should be exchanged? > > > > But as per this Q.2210 the XCO/XCA use a 24 bit sequence number. But > above in Q.703 only 12 bits is suggested for 2M links. How to use this > XCO/XCA for 2M links ? Can we use least significant 12 bits of the XCO FSN > parameter to convey the 12 bit sequence number ? > > > > Pls help me understand this point. > > > > Thanks & Regards > > Santhanakrishnan > >