Re: [MTP3] Change Over procedure for 2M TDM links
"David Laight" <[email protected]> Wed, 6 Apr 2011 09:03:31 +0100
| Newsgroups | gmane.ietf.sigtran |
|---|---|
| Message-ID | <[email protected]> |
> Hi > I was asking in MTP2 level whether 2M links can be used. Also I > wanted the details of ChangeOver procedures like , which > message COO/XCO > should be used and what is the FSN parameter size 12bits or 24bits.... I don't see a problem with putting a 12bit sequence number into a 24bit field (much harder the other way around!). The 2M/1.5M links from Q.703 Annex A certainly are used (or have been used!). We've been asked whether we support them, but only for 'tick box' filling, none of our customers has actually asked us to support them (the difficulty is getting the timeslot data through the tdm cross bar switch and the falcs without generating a 'shear' midway through the tdm frame. My suspicions are the the SIGTRAN protocols are being used for any links that need to carry large traffic loads. David