Re: Number of streams in SCTP Association
"Brian F. G. Bidulock" <[email protected]> Tue, 21 Jun 2011 20:00:38 -0600
| Newsgroups | gmane.ietf.sigtran |
|---|---|
| Organization | http://www.openss7.org/ |
| Message-ID | <[email protected]> |
aditi, RFC 4165/Page 24: The association SHALL contain two sttreams in each direction. Stream 0 is designated for Link Status messages. Stream 1 is designated for User Data messages, as well as Link Status messages that must remain in sequence with the User Data messages. It goes on to say which messages are send on which stream. --brian aditi someshwar wrote: (Tue, 21 Jun 2011 09:29:53) > Thanks Chris, Thanks Padmalochan. > Would the M2PA also use more than 2 streams, or is there a restriction > there? > Regards, > Aditi -- Brian F. G. Bidulock [email protected] http://www.openss7.org/