Re: Unable to use a variable in instruction

Robert Plantz <[email protected]>
Newsgroups gmane.linux.assembly
Message-ID <1192413717.5651.4.camel@ubuntu>
On Sun, 2007-10-14 at 19:37 -0400, A D wrote:
> I'm having strange problem accessing a variable in a gnu assembly language program.
> When i write a code:
> 
> .section .data
>    x = 4

This is equivalent to writing
        .equ  x,4

> mm:
>    .int 1, 2
> 
> .section .text
> .globl _start
> _start:
>    nop

So this instruction:
>    movl x, %ecx   #can't do this 

is trying to move the 4 bytes stored at memory location 4 into the ecx
register. As the OS told you, you cannot do that.

The way to allocate an initialized 32-bit int in the .data section is:

x:     .long  4


-
To unsubscribe from this list: send the line "unsubscribe linux-assembly" in
the body of a message to [email protected]
More majordomo info at  http://vger.kernel.org/majordomo-info.html