Re: use more than 16 HCI Devices at a time with BlueZ?

Uli Sesselmann <[email protected]>
Newsgroups gmane.linux.bluez.user
Message-ID <[email protected]>
Hi Marcel,
> Hi Uli,
>
>   
>> is there a possibility to use more than 16 HCI-Devices at a time with BlueZ?
>> And if not, where is this limitation set? (i would try to raise it on my 
>> own then :) )
>>     
>
> the kernel has no limit besides memory and the usual integer limit. In
> userspace the limit is set to 16. A modified Bluetooth library would be
> enough. I think the constant you look for is HCI_MAX_DEV or something.
> Check the source code. It is easy to spot.
>
>   
Thanks a lot for this hint! :)

greetings,
Uli

-------------------------------------------------------------------------