Fwd: Install Fails on T5240

Jeremy Leonard <[email protected]>
Newsgroups gmane.linux.debian.ports.sparc
Message-ID <CAGVfntVJCq7Wt2HquNDhUr8WCcZKbpg0sX5ga2e-qFhTE6heHA@mail.gmail.com>
On Fri, Jul 25, 2025 at 10:28 AM Jeremy Leonard <[email protected]>
wrote:

>
>
> On Fri, Jul 25, 2025 at 7:21 AM John Paul Adrian Glaubitz <
> [email protected]> wrote:
>
>> Hi Jeremy,
>>
>> On Fri, 2025-07-25 at 06:42 -0400, Jeremy Leonard wrote:
>> > I was attempting a bare-metal install.
>>
>> Could you test whether Solaris 11.4 CBE works fine on your T5240?
>>
>> See:
>> https://www.oracle.com/de/solaris/solaris11/downloads/solaris-downloads.html
>>
>> It's free for non-commercial use.
>>
>> Adrian
>>
>> --
>>  .''`.  John Paul Adrian Glaubitz
>> : :' :  Debian Developer
>> `. `'   Physicist
>>   `-    GPG: 62FF 8A75 84E0 2956 9546  0006 7426 3B37 F5B5 F913
>>
>
> I've downloaded 11.3 I'll work to install 11.3 this evening and report
> back.
>
>
I think I may have hardware issues.

The install failed to boot completely for Solaris 11.3. I received an error:

SUNW-MSG-ID: SUNOS-8000-J0, TYPE: Fault, VER: 1, SEVERITY: Major
EVENT-TIME: Sat Jul 26 01:33:17 UTC 2025
PLATFORM: SUNW,T5240, CSN: 11223344, HOSTNAME: solaris
SOURCE: eft, REV: 1.16
EVENT-ID: 63482a2a-4716-43c2-9a7a-b3fb99198607
DESC: The diagnosis engine encountered telemetry from the listed devices
for which it was unable to perform a diagnosis - no valid path to component
was found in ereport.io.pciex.tl.ptlp.
AUTO-RESPONSE: Error reports have been logged for examination.
IMPACT: Automated diagnosis and response for these events will not occur.
REC-ACTION: Use 'fmadm faulty' to provide a more detailed view of this
event. Use 'fmdump -epV -u 63482a2a-4716-43c2-9a7a-b3fb99198607' to view
the unexpected telemetry. Please refer to the associated reference document
at http://support.oracle.com/msg/SUNOS-8000-J0 for the latest service
procedures and policies regarding this diagnosis.

SUNW-MSG-ID: SUN4V-8002-SP, TYPE: Fault, VER: 1, SEVERITY: Major
EVENT-TIME: Sat Jul 26 01:33:18 UTC 2025
PLATFORM: SUNW,T5240, CSN: 11223344, HOSTNAME: solaris
SOURCE: cpumem-diagnosis, REV: 1.7
EVENT-ID: fe7d5e2f-77d7-40bb-8359-e16d74c53bc9
DESC: The error report generator has received input data that is
inconsistent or improperly formatted.
AUTO-RESPONSE: No automated response.
IMPACT: This error does not affect system operation.  The error which could
not be reported may have more serious impact which cannot be determined.
REC-ACTION: Use 'fmadm faulty' to provide a more detailed view of this
event. The system may need a firmware upgrade. Please retain the error log
file. Please refer to the associated reference document at
http://support.oracle.com/msg/SUN4V-8002-SP for the latest service
procedures and policies regarding this diagnosis.
Jul 26 01:33:28 solaris in.routed[1122]: route 0.0.0.0/24 --> 0.0.0.0
nexthop is not directly connected

I was able to break out of the install and get a shell.

>From there I ran:

fmadm faulty
--------------- ------------------------------------  --------------
---------
TIME            EVENT-ID                              MSG-ID
SEVERITY
--------------- ------------------------------------  --------------
---------
Jul 26 01:33:18 fe7d5e2f-77d7-40bb-8359-e16d74c53bc9  SUN4V-8002-SP  Major


Problem Status    : open
Diag Engine       : cpumem-diagnosis / 1.7
System
    Manufacturer  : unknown
    Name          : SUNW,T5240
    Part_Number   : unknown
    Serial_Number : 11223344
    Host_ID       : 85b10ec0

----------------------------------------
Suspect 1 of 1 :
   Problem class : defect.fw.generic-sparc.erpt-gen
   Certainty   : 100%

   Resource
     FMRI             :
"hc://:chassis-mfg=unknown:chassis-name=SUNW,T5240:chassis-part=unknown:chassis-serial=BDL10502C2:fru-serial=1005LCB-1046DK00F7:fru-part=540790804/motherboard=0"
     Manufacturer     : unknown
     Name             : unknown
     Part_Number      : 540790804
     Revision         : unknown
     Serial_Number    : 1005LCB-1046DK00F7
     Chassis
        Manufacturer  : unknown
        Name          : SUNW,T5240
        Part_Number   : unknown
        Serial_Number : BDL10502C2
     Status           : faulted but still in service

Description : The error report generator has received input data that is
              inconsistent or improperly formatted.

Response    : No automated response.

Impact      : This error does not affect system operation.  The error which
              could not be reported may have more serious impact which
cannot
              be determined.

Action      : Use 'fmadm faulty' to provide a more detailed view of this
event.
              The system may need a firmware upgrade. Please retain the
error
              log file. Please refer to the associated reference document at
              http://support.oracle.com/msg/SUN4V-8002-SP for the latest
              service procedures and policies regarding this diagnosis.

--------------- ------------------------------------  --------------
---------
TIME            EVENT-ID                              MSG-ID
SEVERITY
--------------- ------------------------------------  --------------
---------
Jul 26 01:33:17 63482a2a-4716-43c2-9a7a-b3fb99198607  SUNOS-8000-J0  Major


Problem Status    : open
Diag Engine       : eft / 1.16
System
    Manufacturer  : unknown
    Name          : SUNW,T5240
    Part_Number   : unknown
    Serial_Number : 11223344
    Host_ID       : 85b10ec0

----------------------------------------
Suspect 1 of 2 :
   Problem class : defect.sunos.eft.unexpected_telemetry
   Certainty   : 50%

   Resource
     FMRI             : "hc:///motherboard=0/hostbridge=0/pciexrc=1"
     Manufacturer     : unknown
     Name             : unknown
     Part_Number      : unknown
     Revision         : unknown
     Serial_Number    : unknown
     Chassis
        Manufacturer  : unknown
        Name          : unknown
        Part_Number   : unknown
        Serial_Number : unknown
     Status           : faulted but still in service
----------------------------------------
Suspect 2 of 2 :
   Problem class : fault.sunos.eft.unexpected_telemetry
   Certainty   : 50%

   Resource
     FMRI             : "hc:///motherboard=0/hostbridge=0/pciexrc=1"
     Manufacturer     : unknown
     Name             : unknown
     Part_Number      : unknown
     Revision         : unknown
     Serial_Number    : unknown
     Chassis
        Manufacturer  : unknown
        Name          : unknown
        Part_Number   : unknown
        Serial_Number : unknown
     Status           : faulted but still in service

Description : The diagnosis engine encountered telemetry from the listed
              devices for which it was unable to perform a diagnosis - no
valid
              path to component was found in ereport.io.pciex.tl.ptlp.

Response    : Error reports have been logged for examination.

Impact      : Automated diagnosis and response for these events will not
occur.

Action      : Use 'fmadm faulty' to provide a more detailed view of this
event.
              Use 'fmdump -epV -u 63482a2a-4716-43c2-9a7a-b3fb99198607' to
view
              the unexpected telemetry. Please refer to the associated
              reference document at
http://support.oracle.com/msg/SUNOS-8000-J0
              for the latest service procedures and policies regarding this
              diagnosis.

So this probably isn't the proper place to continue with this since this
list is for Debian. But I don't really know where to go from here. I'm just
trying to start with Sun/Sparc things.

-- 
Jeremy Leonard
[email protected]
Cell: (517) 285-8309
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.