PowerEdge 2650/aacraid: how to initiate failover and replace disk?

Alexander JOLK <[email protected]> Wed, 09 Jul 2003 13:17:56 +0200
Newsgroups gmane.linux.drivers.aacraid.devel
Organization BUF Compagnie
Message-ID <[email protected]>
Hi,

I could use some help for this: one of the disks in my PowerEdge 2650
with Perc3/Di is failing, and I'm getting a replacement disk later
today.  What I need to do now is initiate a failover to the hot spare
disk, and then power off the failing disk in order to replace it.  (No
downtime is my goal, as you can imagine.)

So my question, how do I initiate a failover (from ID 2, which is
failing, to my configured hot spare)?  And then, how do I power off the
disk 2 in order to remove it?

I imagine something along the lines of
afacli
open afa0
disk blink 2
enclusure prepare 2

Thanks for any hints you might be giving,
	Alex


My config: Debian 3.0, kernel 2.4.20, 5x 73GB (1 hot spare, RAID-5 for
the other 4), aacraid driver.

My errors:

Jul  8 21:50:02 edge kernel: aacraid:ID(0:02:0) Medium Error, LBN Range
42919:42943
Jul  8 21:50:02 edge kernel: aacraid:ID(0:02:0) Starting BBR sequence
Jul  8 22:35:45 edge kernel: aacraid:ID(0:02:0); Error Event
[command:0x2a]
Jul  8 22:35:45 edge kernel: aacraid:ID(0:02:0); Medium Error
[k:0x3,c:0xc,q:0x2]
Jul  8 22:35:45 edge kernel: aacraid:ID(0:02:0); Write Error - Auto
Reallocation Failed

-- 
Alexander Jolk         /         BUF Compagnie
tel +33-1 42 68 18 28 /  fax +33-1 42 68 18 29

_______________________________________________
Linux-aacraid-devel mailing list
[email protected]
http://lists.us.dell.com/mailman/listinfo/linux-aacraid-devel
Please read the FAQ at http://lists.us.dell.com/faq or search the list archives at http://lists.us.dell.com/htdig/