| Message-ID | <[email protected]> |
Andrew McCall wrote: > kernel: aacraid:ID(0:01:0); Medium Error, Block Range 18888320 : > 18888447 > kernel: aacraid:ID(0:01:0); Unrecovered Read Error > kernel: aacraid:Container 0 failed REBUILD task: I/O error - drive 0:1:0 > failed > kernel: aacraid:Container 0 started REBUILD task on drive 0:2:0 > > I have recently had to swap drive 0:2:0 after I had a total failure on > it, but this message seems to indicate that drive 0:1:0 is broken too. > There are no orange LED's on the front of the drive though. > > Am I correct in thinking that I need to call Dell to get 0:1:0 replaced? You should get that disk replaced, it's the SMART system predicting a disk failure. Try "disk show smart" and "disk show defects 01" commands in afacli. > I have also noticed that when using the afacli command, that the > controller seems to think it hasn't got a battery - is this right? Yes, PE 2450 with PERC3/Si has no backup battery so RAID controller write-back cache is disabled by default. PE 2550 with PERC 3/Di has backup battery. -- // Tomi Hakala // Song Networks, System Services _______________________________________________ Linux-aacraid-devel mailing list [email protected] http://lists.us.dell.com/mailman/listinfo/linux-aacraid-devel Please read the FAQ at http://lists.us.dell.com/faq or search the list archives at http://lists.us.dell.com/htdig/