Re: Problem with connection of EtherExpress Pro100 to a 10/100 switch

Donald Becker <[email protected]> Fri, 17 Oct 2003 18:02:28 -0400 (EDT)
Newsgroups gmane.linux.drivers.eepro100.devel
Message-ID <[email protected]>
On Fri, 17 Oct 2003, Ricardo Jorge da Fonseca Marques Ferreira wrote:

> On Friday 17 October 2003 19:49, Donald Becker wrote:
> > My current guess is
> >   Your switch really does have auto-crossover
> >       (although the on-line datasheet does list that feature)
> >   Something about the on-board NIC triggers the switch to mistakenly
> >      cross-over.

Well this is back to our leading theory.

Adding
    Port 16 works because it is internally crossed over, due to the
    switch using a new transceiver chip on an old board layout.

I would be nice to understand this problem, but since you have a
work-around (however little sense it makes) we may have to wait for
additional reports to understand the problem.

-- 
Donald Becker				[email protected]
Scyld Computing Corporation		http://www.scyld.com
914 Bay Ridge Road, Suite 220		Scyld Beowulf cluster system
Annapolis MD 21403			410-990-9993