Re: Problem with connection of EtherExpress Pro100 to a 10/100 switch
Donald Becker <[email protected]> Fri, 17 Oct 2003 18:02:28 -0400 (EDT)
| Newsgroups | gmane.linux.drivers.eepro100.devel |
|---|---|
| Message-ID | <[email protected]> |
On Fri, 17 Oct 2003, Ricardo Jorge da Fonseca Marques Ferreira wrote:
> On Friday 17 October 2003 19:49, Donald Becker wrote:
> > My current guess is
> > Your switch really does have auto-crossover
> > (although the on-line datasheet does list that feature)
> > Something about the on-board NIC triggers the switch to mistakenly
> > cross-over.
Well this is back to our leading theory.
Adding
Port 16 works because it is internally crossed over, due to the
switch using a new transceiver chip on an old board layout.
I would be nice to understand this problem, but since you have a
work-around (however little sense it makes) we may have to wait for
additional reports to understand the problem.
--
Donald Becker [email protected]
Scyld Computing Corporation http://www.scyld.com
914 Bay Ridge Road, Suite 220 Scyld Beowulf cluster system
Annapolis MD 21403 410-990-9993