Linksys PCM200 v2 now works with updated driver and diag.
Donald Becker <[email protected]>
| Newsgroups | gmane.linux.drivers.tulip.general |
|---|---|
| Message-ID | <[email protected]> |
On Fri, 2 Aug 2002, Brett Dikeman wrote: > At 12:57 PM -0400 8/2/02, Donald Becker wrote: > > > >Could you get me the full name and version of the board? > >> well, here's physical ID info, from packaging: > >> Model Number: PCM200 ver 2 > > tulip-diag -eee > It thinks its a V1.0 card :-)...see below. Hmmm, I'll leave the name as v3 with the justification that 1+2=3 ;-> > Oh, and interestingly, inserting the card caused one of those > infamous spurious interrupts, which I spent a couple hours IRQ7? That's a hardware glitch. > >I do want to figure out what register read "locks" the transceiver to > >one address. > > ok, what do you need to figure that out? If push comes to shove, I > can make the box accessible... I should be able to track this down on my own. > EEPROM contents (256 words): ... > 0x00: 0985 0002 0000 0000 0400 9e5a ec9e 0000 __________Z_____ > 0x08: 0000 0400 0000 0000 0000 0000 0000 0100 ________________ > 0x10: ab09 1737 ab09 1737 ffff 0202 0000 804c __7___7_______L_ > 0x18: 0000 0000 0000 0000 0000 0000 0000 0000 ________________ > 0x20: 0000 0000 0000 0000 0000 0000 0000 0000 ________________ > 0x28: 0040 0060 0000 0000 0000 0000 0000 0000 @_`_____________ > 0x30: 0000 0000 0000 0000 0000 0000 0000 0000 ________________ > 0x38: 0000 0000 0000 0000 0000 0000 0000 f9d4 ________________ ... > ID block CRC 0x09 (vs. 00). > Full contents CRC 0xf9d4 (read as 0xf9d4). At least they got the CRC right. > 0xa0: 0313 4943 2053 d104 0213 21ab 0602 2201 __CIS _____!___" > 0xa8: 0102 2202 0205 9680 0098 0522 0002 f5e1 ___"______"_____ > 0xb0: 2205 0302 1501 0546 4c00 6e69 736b 7379 _"____F__Linksys > 0xb8: 4500 6874 7265 6146 7473 4920 746e 6765 _EtherFast Integ > 0xc0: 6172 6574 2064 3031 312f 3030 4320 7261 rated 10/100 Car > 0xc8: 4264 7375 5020 2043 6143 6472 5028 4d43 dBus PC Card(PCM > 0xd0: 3032 2930 5600 2e31 0030 ff00 0400 0306 200)_V1.0_______ This definitely isn't the first version Linksys put out. I'm guessing that some new guy didn't know to update the CIS entry. -- Donald Becker [email protected] Scyld Computing Corporation http://www.scyld.com 410 Severn Ave. Suite 210 Second Generation Beowulf Clusters Annapolis MD 21403 410-990-9993 _______________________________________________ tulip mailing list, [email protected] To change to digest mode or unsubscribe visit http://www.scyld.com/mailman/listinfo/tulip