Problem moving from Redhat 7.1 to RedHat 8.0
Ross Macintyre <[email protected]> Mon, 22 Sep 2003 16:49:07 +0100 (GMT Daylight Time)
| Newsgroups | gmane.linux.drivers.vortex.devel |
|---|---|
| Message-ID | <[email protected]> |
I manage 2 groups of machines (as well as others) that are giving me horrendous problems trying to put RedHat 8.0 on them. They are old Viglen machines. One group are Genie2 and the others are Contender2's. They contain 'Boomerang' and 'Cyclone' ethernet cards. I have left one machine at 7.1 and it still works fine, The other 30 machines have all had RedHat 8.0 installed on them and at first all seemed to be working fine but now I notice that they all lose their connections to the network after about 5 to 10 minutes after a reboot. It could be that in some cases the network card has just gone flakey, but it would seem a hell of a coincidence if 30 went at once and the one that I left in a 7.1 machine is still ok!! Some machines are producing this: NETDEV WATCHDOG: eth0: transmit timed out eth0: transmit timed out, tx_status 00 status e000. diagnostics: net 0cc0 media 8802 dma 00000000. Flags; bus-master 1, dirty 1(1) current 17(1) Transmit list 00000000 vs. c2462240. 0: @c2462200 length 80000092 status 80000092 1: @c2462240 length 8000002a status 0000002a 2: @c2462280 length 80000092 status 00000092 3: @c24622c0 length 80000092 status 00000092 4: @c2462300 length 80000092 status 00000092 5: @c2462340 length 80000092 status 00000092 6: @c2462380 length 80000092 status 00000092 7: @c24623c0 length 80000092 status 00000092 8: @c2462400 length 8000002a status 0000002a 9: @c2462440 length 8000002a status 0000002a 10: @c2462480 length 8000002a status 0000002a 11: @c24624c0 length 800000c6 status 000000c6 12: @c2462500 length 80000092 status 00000092 13: @c2462540 length 80000092 status 00000092 14: @c2462580 length 80000092 status 00000092 15: @c24625c0 length 80000092 status 80000092 eth0: Resetting the Tx ring pointer. eth0: Transmit error, Tx status register 90. Flags; bus-master 1, dirty 1(1) current 17(1) Transmit list 02462280 vs. c2462240. 0: @c2462200 length 80000092 status 80000092 1: @c2462240 length 8000002a status 0000002a 2: @c2462280 length 80000092 status 00000092 3: @c24622c0 length 80000092 status 00000092 4: @c2462300 length 80000092 status 00000092 5: @c2462340 length 80000092 status 00000092 6: @c2462380 length 80000092 status 00000092 7: @c24623c0 length 80000092 status 00000092 8: @c2462400 length 8000002a status 0000002a 9: @c2462440 length 8000002a status 0000002a 10: @c2462480 length 8000002a status 0000002a 11: @c24624c0 length 800000c6 status 000000c6 12: @c2462500 length 80000092 status 00000092 13: @c2462540 length 80000092 status 00000092 14: @c2462580 length 80000092 status 00000092 15: @c24625c0 length 80000092 status 80000092 I have only seen this on about half a dozen machines but I would be interested to know if this meant that they should go in the bin (or not). The trouble here of course is that I can't easily check the 30 machines. So, does this indicate a hardware error? Anyway thanks in advance to anyone who can offer advice, either about the message above, or in general about problems with the 3c59x module in RedHat8.0. I did try recompiling the 7.1 3c59x.c file under 8.0 but it still didn't work. I also tried updating the BIOS but also no joy. Also my kernel is 2.4.20-20.8. Cheers, Ross -- Ross Macintyre Heriot-Watt University [email protected] _______________________________________________ vortex mailing list [email protected] http://www.scyld.com/mailman/listinfo/vortex