Re: Re: 3c905 errors:
Bogdan Costescu <[email protected]> Fri, 10 Oct 2003 18:20:42 +0200 (CEST)
| Newsgroups | gmane.linux.drivers.vortex.devel |
|---|---|
| Message-ID | <Pine.LNX.4.44.0310101813570.22247-100000@kenzo.iwr.uni-heidelberg.de> |
On Thu, 9 Oct 2003, Steven Timm wrote: > Up to this point I haven't been able to observe one of these errors as > it happens, but over the course of this week there has been an average > of two or three of them per node in a 240-node cluster. I always advise against using force media type, but would it be possible to force it for one or more computers to 100Mbit, full-duplex ? According to what you say above, it should be apparent in just a few days (if not sooner) what the outcome is. Please keep in mind to force both sides of the connection: the network card (with 'mii-diag -F') and the switch port. > Any advice on what might be happening? A completely blind shot: are the network cables all coming from the same manufacturer ? -- Bogdan Costescu IWR - Interdisziplinaeres Zentrum fuer Wissenschaftliches Rechnen Universitaet Heidelberg, INF 368, D-69120 Heidelberg, GERMANY Telephone: +49 6221 54 8869, Telefax: +49 6221 54 8868 E-mail: [email protected] _______________________________________________ vortex mailing list [email protected] http://www.scyld.com/mailman/listinfo/vortex