Re: 3c905CX-TXM link problems

Bogdan Costescu <[email protected]> Tue, 21 Oct 2003 00:35:17 +0200 (CEST)
Newsgroups gmane.linux.drivers.vortex.devel
Message-ID <Pine.LNX.4.44.0310210026440.17148-100000@kenzo.iwr.uni-heidelberg.de>
On Mon, 20 Oct 2003, Raul Dias wrote:

>  - Is this a driver problem?  So it will be correct some time in the
> future.

The driver used to do the equivalent of 'mii-diag -R' upon loading, but
this resets any link that might have been established until that point.  
This is particularly annoying with some Cisco switches that only activate
the port 1 minute after the link was established. I suggested at that time
to make the reset a module option defaulting to disabled (the present 
behaviour), but it didn't happen... It seems that not many people are 
missing it :-)

>  - Is this model (3C905CX-TXM) , garbage? So I should not rely on this
> and use a different model.

Well, I've had very good experience over years with 905B and 905C cards 
(notice 905C without X). I only have 4 905CX cards that are in use at the 
moment, so I can't do any testing.

>  - I am expect to use 'mii-tool -R' on boot and not to worry about the
> card quality (which is good)?

That's also an option :-) You could even do it more or less automatically 
in /etc/modules.conf with a "post-install" statement.

-- 
Bogdan Costescu