Re: problems w/3c59x on 3CCFE575BT

Donald Becker <[email protected]>
Newsgroups gmane.linux.drivers.vortex.devel
Message-ID <[email protected]>
On Sun, 22 Dec 2002, dean gaudet wrote:
> # vortex-diag -ee -aa -m
> vortex-diag.c:v2.05 5/15/2001 Donald Becker ([email protected])
...
> Index #1: Found a 3CCFE575BT CardBus adapter at 0x4800.
...
> EEPROM contents (256 words, offset 0x30):
>  0x000: 10b7 5157 0007 0000 0001 0200 4000 0000
>  0x008: 0000 0000 0000 0000 0000 0000 0000 0000
>  0x010: 0000 0000 0000 0000 0090 0000 10b7 5b57
>  0x018: 0000 0000 0000 0000 0000 0000 0109 0a0a
>  0x020: 0000 0060 0000 0000 0000 0000 0000 0000
>  0x028: 0000 0000 0000 0000 0000 0000 0000 0000
>  0x030: 0050 04b4 e729 5157 c6fc 0036 4757 6d50
>  0x038: 3000 0009 0050 04b4 e729 2010 0000 0006
>  0x040: 32a6 1570 0000 0060 0007 0000 0000 00be

I checked this against the reference 3ccfe575bt that I have here at
the Scyld offices.  Except for the station address and date, the EEPROM
contents match the properly working device that I have here.

Verify that you are not passing in a module option.

>  MII PHY 0 at #0 transceiver registers:
>    3000 282d 0300 e54b 00a1 45e1 0001 0000

This transceiver model is slightly different than on my card.  Both are
TDK 78q2120 parts, but your transceiver is a newer rev. 11 chip (e543
vs. e54b).


-- 
Donald Becker				[email protected]
Scyld Computing Corporation		http://www.scyld.com
410 Severn Ave. Suite 210		Scyld Beowulf cluster system
Annapolis MD 21403			410-990-9993