Re: Problems detecting 100Mbps with 3c59x (Vortex)
Donald Becker <[email protected]>
| Newsgroups | gmane.linux.drivers.vortex.devel |
|---|---|
| Message-ID | <[email protected]> |
On Mon, 30 Dec 2002, CJ Kucera wrote: > On Mon, Dec 30, 2002 at 02:35:05PM -0500, Donald Becker wrote: > > First: do not force full duplex! > > > > When your switch allows forcing the setting, you have a long-term > > network administration problem. > > When your switch cannot be set, you have an immediate bug. > > Hm... I had figured since my other ethernet cards had autodetected > 100baseTx-FD, that it was a viable mode for me to be using. Full duplex is only correct when it is auto-negotiated. > I presume from when you said "Note that this is required for the > 3c595 and 3c590 boards" you mean that autodetection is something that > just isn't possible with the 3c595? Correct. The 3c595 pre-dated autonegotiation, and was one of the earliest PCI designs. The 3c905 was a major improvement: it added autonegotiation, as well as a much more effective architecture for bus-master transfers. > > I don't recommend using an old 590 series card if you care about > > performance. > > Even a rtl8139 will have far better performance. > > Heh. Yeah, I figured they'd probably not be great, but they have the > distinct advantage of being the cards I happen to already own. :) > Still, the 100Mbps mode on the 3c595 should do better than the 10Mbps, > right? Or is the difference between the two on the 3c595 negligible? The problem is that the 3c590 series has a single-region bus master capability. CPU must do a substantial amount of the work transferring packets: not as much as a NE2000 clone, but significantly more than with more modern designs. And for the $5-$10 that a new low-end Ethernet NIC will cost, the 3c590 series should be relagated to stand-by use only. > > What is confliciting? > I was referring to the differences between these two lines: > > Transceiver type in use: 100baseTX. > and > > Transceiver selection: 10baseT. Yes, you got it: it's the difference between the configuration EEPROM values, and what the chip is currently configured to use. > So, just to clarify, on a 10/100 switch, the 3c595 will *always* go with > 10 as opposed to 100? The 3c595 can only sense the speed. On a autonegotiating switch the initial offered link beat is 10baseT. Thus the 3c595 will always stay at 10baseT. A long time ago the driver tried to offer 100baseTx link beat for a few seconds when started. But this jams most 10baseT repeaters.. a very bad thing. And there is a race condition when communicating with a link partner trying to do the same thing. Autonegotiation is really a Very Good Thing. It is a _requirement_ for a plug-and-play networking. http://scyld.com/expert/NWay.html -- Donald Becker [email protected] Scyld Computing Corporation http://www.scyld.com 410 Severn Ave. Suite 210 Scyld Beowulf cluster system Annapolis MD 21403 410-990-9993 _______________________________________________ vortex mailing list [email protected] http://www.scyld.com/mailman/listinfo/vortex