Re: [Fwd: problem with dual 3com card]
"maillists (josef ""radinger)" <[email protected]>
| Newsgroups | gmane.linux.drivers.vortex.devel |
|---|---|
| Message-ID | <[email protected]> |
On Mon, 2003-06-02 at 13:49, Bogdan Costescu wrote: > On 27 May 2003, maillists (josef radinger) wrote: > > > i cannot set it into full-duplex mode just by issuing module-parameters > > (neither options=0x204,0x204 nor full_duplex=1,1 works) > > Could you set the debug level to a higher value and watch the logs for > anything media-related from the cards (obviously dumped after the kernel > finishes booting) ? > And maybe output from mii-diag when the driver is forced with the above > options... hi here are the outputs from vortex-diag -aa, -ee, -mm mii-diag and /var/log/messages *-diag only applied on eth0 (eth1 was not connected) 3c59x was loaded with full_duplex debug=7 and the switch was on full_duplex mii-diag reports link status down, and i was not able to send any packets. yours josef
messages.txt
(text/plain, 1.7 KB)
Jun 4 15:25:54 faramir syslogd 1.3-3: restart. Jun 4 15:25:54 faramir syslog: syslogd startup succeeded Jun 4 15:25:54 faramir kernel: klogd 1.3-3, log source = /proc/kmsg started. Jun 4 15:25:54 faramir kernel: Inspecting /boot/System.map-2.2.23-8 Jun 4 15:25:54 faramir syslog: klogd startup succeeded Jun 4 15:25:54 faramir kernel: Loaded 7410 symbols from /boot/System.map-2.2.23-8. Jun 4 15:25:54 faramir kernel: Symbols match kernel version 2.2.23. Jun 4 15:25:54 faramir kernel: Loaded 112 symbols from 5 modules. Jun 4 15:25:54 faramir kernel: 3c59x.c:v0.99Y 12/16/2002 Donald Becker, [email protected] Jun 4 15:25:54 faramir kernel: http://www.scyld.com/network/vortex.html Jun 4 15:25:54 faramir kernel: eth0: 3Com 3c982 Server Tornado at 0x7880, 00:04:75:cd:ba:15, IRQ 9 Jun 4 15:25:54 faramir kernel: 8K buffer 5:3 Rx:Tx split, autoselect/Autonegotiate interface. Jun 4 15:25:54 faramir kernel: MII transceiver found at address 24, status 7809. Jun 4 15:25:54 faramir kernel: Using bus-master transmits and whole-frame receives. Jun 4 15:25:54 faramir kernel: eth1: 3Com 3c982 Server Tornado at 0x7c00, 00:04:75:cd:ba:16, IRQ 11 Jun 4 15:25:54 faramir kernel: 8K buffer 5:3 Rx:Tx split, autoselect/Autonegotiate interface. Jun 4 15:25:54 faramir kernel: MII transceiver found at address 24, status 780d. Jun 4 15:25:54 faramir kernel: Using bus-master transmits and whole-frame receives. Jun 4 15:25:54 faramir kernel: eth0: MII #24 status 7809, link partner capability 0000, setting full-duplex. Jun 4 15:25:54 faramir kernel: eth1: MII #24 status 780d, link partner capability 0000, setting full-duplex. Jun 4 15:25:54 faramir syslog: syslogd shutdown succeeded
mii-diag.txt
(text/plain, 215 B)
Basic registers of MII PHY #24: 3000 7809 0040 6177 0541 0000 0000 0000. Basic mode control register 0x3000: Auto-negotiation enabled. Basic mode status register 0x7809 ... 7809. Link status: not established.
vortexdiaga.txt
(text/plain, 1.2 KB)
vortex-diag.c:v2.02 7/1/2000 Donald Becker ([email protected]) http://www.scyld.com/diag/index.html Assuming a 3Com Generic Vortex/Boomerag/Cyclone adapter at 0x7880. The Vortex chip may be active, so FIFO registers will not be read. To see all register values use the '-f' flag. Initial window 4, registers values by window: Window 0: 0000 0000 0000 0000 0000 00bf ffff 0000. Window 1: FIFO FIFO 0700 0000 0000 007f 0000 2000. Window 2: 0400 cd75 15ba 0000 0000 0000 0012 4000. Window 3: 0000 0380 05ea 0020 000a 0800 0800 6000. Window 4: 0000 0000 0000 0cfc 0001 8080 0000 8000. Window 5: 1ffc 0000 0000 0600 0815 06de 06c6 a000. Window 6: 0000 0000 0000 0000 0000 0000 003c c000. Window 7: 0000 0000 0000 0000 0000 0000 0000 e000. Vortex chip registers at 0x7880 0x7890: **FIFO** 00000000 00000000 *STATUS* 0x78A0: 00000020 0f8b0200 00080000 00001404 0x78B0: 00000000 5806a7fa 0f8b0000 00080004 Indication enable is 06c6, interrupt enable is 06de. No interrupt sources are pending. Transceiver/media interfaces available: 100baseTx 10baseT. Transceiver type in use: Autonegotiate. MAC settings: full-duplex. Station address set to 00:04:75:cd:ba:15. Configuration options 0012.
vortexdiage.txt
(text/plain, 1 KB)
vortex-diag.c:v2.02 7/1/2000 Donald Becker ([email protected]) http://www.scyld.com/diag/index.html Assuming a 3Com Generic Vortex/Boomerag/Cyclone adapter at 0x7880. EEPROM contents (64 words): 0x000: 0004 75cd ba15 9805 054e 0048 5454 6d50 0x008: 2940 0800 0004 75cd ba15 0010 0000 00aa 0x010: 72a2 0000 0000 0380 0000 0000 0000 10b7 0x018: 1201 000a 0000 6300 0000 0000 0000 0000 0x020: 00f6 1234 5600 0000 0000 0000 0000 0000 0x028: 0000 0000 0000 0000 0000 0000 0000 0000 0x030: ffff ffff ffff ffff ffff ffff ffff ffff 0x038: ffff ffff ffff ffff ffff ffff ffff ffff The word-wide EEPROM checksum is 0x5603. Parsing the EEPROM of a 3Com Vortex/Boomerang: 3Com Node Address 00:04:75:CD:BA:15 (used as a unique ID only). OEM Station address 00:04:75:CD:BA:15 (used as the ethernet address). Manufacture date (MM/DD/YYYY) 10/14/2002, division H, product TT. Options: none. Vortex format checksum is incorrect (002b vs. 10b7). Cyclone format checksum is incorrect (0x95 vs. 0xf6). Hurricane format checksum is correct (0xf6 vs. 0xf6).
vortexdiagm.txt
(text/plain, 1.2 KB)
vortex-diag.c:v2.02 7/1/2000 Donald Becker ([email protected]) http://www.scyld.com/diag/index.html Assuming a 3Com Generic Vortex/Boomerag/Cyclone adapter at 0x7880. MII PHY found at address 24, status 7809. MII PHY 0 at #24 transceiver registers: 3000 7809 0040 6177 0541 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 1000 0201 0000 0000 0000 0290 0300 0000 003c 1002 0f00 ff40 002c 0000 0010 000b. MII PHY #24 transceiver registers: 3000 7809 0040 6177 0541 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 1000 0200 0000 0000 0000 036c 0400 0000 003c 1002 0f00 ff40 002c 0000 0010 000b. Basic mode control register 0x3000: Auto-negotiation enabled. Basic mode status register 0x7809 ... 7809. Link status: not established. Capable of 100baseTx-FD 100baseTx 10baseT-FD 10baseT. Able to perform Auto-negotiation, negotiation not complete. Vendor ID is 00:10:18:--:--:--, model 23 rev. 7. No specific information is known about this transceiver type. I'm advertising 0541: Flow-control 100baseTx-FD 10baseT-FD Advertising no additional info pages. IEEE 802.3 CSMA/CD protocol. Link partner capability is 0000:. Negotiation did not complete.