Re: Connection to 100megabit linksys switch flakey

Bogdan Costescu <[email protected]> Mon, 13 Oct 2003 19:51:59 +0200 (CEST)
Newsgroups gmane.linux.drivers.vortex.devel,gmane.linux.drivers.vortex.user
Message-ID <Pine.LNX.4.44.0310131950090.15115-100000@kenzo.iwr.uni-heidelberg.de>
On Mon, 13 Oct 2003, John Post wrote:

> eth0: negotiated 100baseTx-FD flow-control, link ok
> ...
>   link partner: 100baseTx-FD 100baseTx-HD 10baseT-FD 10baseT-HD
> flow-control

OK, now it's completely different. It shows that both ends use 
autonegotiation; that the card was able to sense the capabilities of the 
switch and that the both agreed on using 100Mbit full-duplex.

So, please go on with my suggestion of disabling power management...

-- 
Bogdan Costescu

IWR - Interdisziplinaeres Zentrum fuer Wissenschaftliches Rechnen
Universitaet Heidelberg, INF 368, D-69120 Heidelberg, GERMANY
Telephone: +49 6221 54 8869, Telefax: +49 6221 54 8868
E-mail: [email protected]

_______________________________________________
vortex mailing list
[email protected]
http://www.scyld.com/mailman/listinfo/vortex