Re: Re: General question
Stephan von Krawczynski <[email protected]>
| Newsgroups | gmane.linux.enbd.general |
|---|---|
| Organization | ith Kommunikationstechnik GmbH |
| Message-ID | <[email protected]> |
On Mon, 6 Jun 2005 22:06:17 +0200 (MET DST) "Peter T. Breuer" <[email protected]> wrote: > [...] > > This is from nbd-2.4.32pre.tgz I downloaded around 6th April 2005. > > Looks fine - seems you just have the 2.4 code, and anyway it seems > maybe I left it up to the admin to set show_errs. But I think it is > probably OK to set it on going into a raid array when its a FR1 array. > And since only FR1 sends the two ioctls above, it should be fine to add > the appropriate code (sketched above) there. > > I've done it now in my copy. Can I download this version somewhere? Just to be sure we are talking of the same thing in the future. I just downloaded the version from 6th June, and it is not in there. One thing that looks almost like a bug is the fact, that after removal of a failing unit the show_err state gets dropped in the version I have. So if the device is re-enabled (because network comes back) it won't work a second time, but hang _then_. You would have to set the flag manually again after such a failure, but you don't know when... Basically I think the approach to set it during this ioctl looks best. -- Regards, Stephan