Re: Question about PERC battery failure messages....
Alain Péan <[email protected]>
| Newsgroups | gmane.linux.hardware.dell.poweredge |
|---|---|
| Message-ID | <[email protected]> |
Hi Becky, Le 21/09/2015 21:07, Becky Ligon a écrit : > I have the DELL R720XD with the embedded PERC 710 MINI. Randomly, on > any one of the 16 servers, the following messages show up in the IDRAC > event log: > > Fri Sep 18 2015 23:55:40 The PERC1 battery has failed. > > > Fri Sep 18 2015 23:56:40 The PERC1 battery is operating normally. > > > > Can someone explain to me what is going on here? Is this something to > be concerned about? No, nothing to be concerned about, it is just for information. The controller battery goes through a discharging/charging cycle a regular interval. Perhaps, it is better that there is no power supply shortage when the battery is discharging, but that's all. I think this cycle is a test to insure taht the battery is still in good shape. But Dell OMSA issue a warning when this happens. Alain -- Administrateur Système/Réseau Laboratoire de Photonique et Nanostructures (LPN/CNRS - UPR20) Centre de Recherche Alcatel Data IV - Marcoussis route de Nozay - 91460 Marcoussis Tel : 01-69-63-61-34 _______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge