Jeff Boyce,
Thanks for the information...

Santosh,
Is there anyway Jeff Boyce can update this Hard drive to ES68 version.

Regards
Muneer

From: Jeff Boyce [mailto:[email protected]]
Sent: Wednesday, November 18, 2015 12:45 AM
To: K, Muneer; linux-poweredge-Lists
Cc: Ponnandi, Soorej; Gore, Santosh
Subject: Re: [Linux-PowerEdge] Hard Drive firmware update issue with DSU

Muneer -

 1.  The drive with ComponentID=00000 was not purchased from Dell, but from a third party retailer.  This was because Dell only had refurbished drives available with a 1-year warranty, while the retailer had new drives available with a full 5-year manufacturer warranty.  The price was the same between the two options.

2.  The new drive is the exact same make and model as the other drives (Seagate ST3300657SS).  Does the different ComponentID numbers actually make them different drives?

3.  The Seagate support site identifies the current firmware for the drive as 000B, released on 8/13/2012.  The Dell support site identifies the current firmware for the drive as ES68, released on 6/10/2015.

4.  I would like to have all drives using the same firmware since they are all the same make and model of drive.  Is that possible?  Is there a way to update this drive with the firmware (ES68) listed on the Dell support site?

Thanks.
Jeff

On 11/17/2015 5:36 AM, [email protected]<mailto:[email protected]> wrote:

Dell - Internal Use - Confidential
Hi Jeff,
The Component ID, which has 00000 is from Dell or from some other Vendor?. If it is from some other Vendor then DUP update will not work. Please let us know.

Thanks
Muneer

From: Gore, Santosh
Sent: Monday, November 16, 2015 10:27 PM
To: DUP_FW_IEIC_SCRUM
Cc: Ponnandi, Soorej
Subject: FW: [Linux-PowerEdge] Hard Drive firmware update issue with DSU


Dell - Internal Use - Confidential
Hi Team,

Please work with "Jeff" to root cause the issue reported with the HDD inventory.   The componentID is incorrect (00000) for one of the drive.

HDD inventory from the system:
<Device componentID="20796" enum="CtrlId 0 DeviceId 0" display="ST3300657SS">
<Application componentType="FRMW" version="ES68" display="Firmware for - Disk 0 in Backplane 0 of PERC H700 Integrated Controller 0 "/>
</Device>
<Device componentID="20796" enum="CtrlId 0 DeviceId 1" display="ST3300657SS">
<Application componentType="FRMW" version="ES68" display="Firmware for - Disk 1 in Backplane 0 of PERC H700 Integrated Controller 0 "/>
</Device>
<Device componentID="00000" enum="CtrlId 0 DeviceId 2" display="ST3300657SS">
<Application componentType="FRMW" version="000B" display="Firmware for - Disk 2 in Backplane 0 of PERC H700 Integrated Controller 0 "/>
</Device>
<Device componentID="20796" enum="CtrlId 0 DeviceId 3" display="ST3300657SS">
<Application componentType="FRMW" version="ES68" display="Firmware for - Disk 3 in Backplane 0 of PERC H700 Integrated Controller 0 "/>


Thanks
Santosh.

-----Original Message-----
From: linux-poweredge-bounces-Lists On Behalf Of Jeff Boyce
Sent: Friday, November 13, 2015 10:05 PM
To: Ponnandi, Soorej ; linux-poweredge-Lists
Subject: Re: [Linux-PowerEdge] Hard Drive firmware update issue with DSU

Soorej -

I have run the inventory report as you requested, and have attached it to this email. I assume it may get stripped off going to the mailing list so I cc'd you directly also. I glanced at the xml file and the only thing that looks like it might be significant is that the replaced disk has a componentID=00000, whereas all the other disks show a componentID=20796. Not sure why, since they are all clearly the same model drives. I hope this help you understand the issue and we can work to resolve it. Thanks.

Jeff


On 11/12/2015 8:31 PM, [email protected]<mailto:[email protected]> wrote:
> Dell - Internal Use - Confidential
> Hi Jeff,
>
> This could be due to the latest update list (Catalog) not having any updates for Disk 2 componentID. We need the inventory report of the platform for root causing this issue.
>
> Please execute the following commands as root user to get inv report.
>
> # yum install invcol_V8336_LN64_15.06.00_A00.x86_64
> # sh /usr/libexec/dell_dup/invcol_V8336_LN64_15.06.00_A00
> -outc=/tmp/inv.xml
>
> Send us the inv.xml file from /tmp directory to understand the issue better.
>
> Thanks,
> Soorej
>
>
>
>
> -----Original Message-----
> From: linux-poweredge-bounces-Lists On Behalf Of Jeff Boyce
> Sent: Wednesday, November 11, 2015 12:16 AM
> To: linux-poweredge-Lists
> Subject: [Linux-PowerEdge] Hard Drive firmware update issue with DSU
>
> Greetings -
>
> Well it looks like a recent drive replacement has created a domino effect for me with a firmware update and now an OMSA installation issue. I will hold the OMSA issue for another email, as I am still have a little research to try to identify and resolve the issue.
>
> The basics of the firmware update issue that I have is that the DSU inventory identifies that I have drives (same manufacturer and model) showing different firmware, but that running the update does not update the firmware on the drive that is not shown as the current version.
> Details of the dsu output are below. My system is a PE T610 and I have
> 4 drives installed configured in a RAID 5 (3 active drives and 1 hot
> spare) on a PERC H700 Controller. The model of the drive replaced (all drives are the same model) is a Seagate SAS 300GB, ST3300657SS. The Seagate support site identifies the current firmware for the drive as 000B, released on 8/13/2012. The Dell support site identifies the current firmware for the drive as ES68, released on 6/10/2015. The new drive I installed shows a firmware version of 000B, while the firmware of the three original drives is shown as ES68. This is shown in the dsu --inventory results below (all other firmware on the box is up-to-date and is not shown). However when the dsu update is run it only identifies the first drive in the backplane (which has current firmware) and does not make any reference to the other three drives, and in particular the drive that has firmware 000B. So my question becomes, how do I updated the firmware in one specific drive? Is this a bug in the implementation of the dsu utility?
>
> Please cc any responses directly to me, as I only receive the daily digest of this mailing list. Thanks.
>
> [root@earth ~]# dsu --inventory
> Getting System Inventory...
>
> 8. Firmware for - Disk 0 in Backplane 0 of PERC H700 Integrated
> Controller 0 ( Version : ES68 ) 9. Firmware for - Disk 2 in Backplane
> 0 of PERC H700 Integrated Controller 0 ( Version : 000B )
>
> [root@earth ~]# dsu
> Getting System Inventory...
> Determining Applicable Updates...
>
> |-----------Dell System Updates-----------|
> [ ] represents 'not selected'
> [*] represents 'selected'
> [-] represents 'Component already at repository version (cannot be selected)'
> Choose: q - Quit without update, c to Commit, - To Select/Deselect, a
> - Select All, n - Select None
>
> [-]6 Firmware for - Disk 0 in Backplane 0 of PERC H700 Integrated
> Controller 0 Current Version : ES68 same as : ES68
>
> Enter your choice : q
> [root@earth ~]#
>
>
> --
>
> Jeff Boyce
> Meridian Environmental
> www.meridianenv.com<http://www.meridianenv.com>
>
> _______________________________________________
> Linux-PowerEdge mailing list
> [email protected]<mailto:[email protected]>
> https://lists.us.dell.com/mailman/listinfo/linux-poweredge

--

Jeff Boyce
Meridian Environmental
www.meridianenv.com<http://www.meridianenv.com>



--



Jeff Boyce

Meridian Environmental

Meridianenv.com

_______________________________________________
Linux-PowerEdge mailing list
[email protected]
https://lists.us.dell.com/mailman/listinfo/linux-poweredge
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.