Re: R720XD dead after IDRAC update trial

Grzegorz Bakalarski <[email protected]>
Newsgroups gmane.linux.hardware.dell.poweredge
Message-ID <CAG2dwFPD=nRtSwEtPwA2Uq-ifM07rCUV5z-VLrRStud+9TT2vw@mail.gmail.com>
Hi

We tried all these voo-doo's to no avail (each several time for 2-5 min).

We also contacted support (the brick is still under warranty). Support
advice was the same (unplug, keep power button or keep reset idrac (i-icon)
for 20s).

Support gave 2 more hints:  (a)  clear NVRAM using NVRAM jumper on MB, (b)
take off all equipment from a server except CPU #1 , one DIMM, one PSU and
system board.

Nothing helped. Server does not boot OS, no VGA display, no IP connection
to iDRAC, nothing on serial port. The only 2 positives: both PSU have
power, disks start flashing after power-on.

Support decided to replace MB. Waiting for serviceman ...

Grzegorz

2016-04-08 20:30 GMT+02:00 Luke Pyzowski <[email protected]>:

> I've had this exact type of issue, and holding the power button as
> mentioned below fixed the issue for me. Additionally, I'd recommend pulling
> the CMOS battery out if that fails.
>
> Luke Pyzowski
>
>
> -----Original Message-----
> From: [email protected] [mailto:
> [email protected]] On Behalf Of Stephen Dowdy
> Sent: Friday, April 08, 2016 11:39 AM
> To: Grzegorz Bakalarski
> Cc: linux-poweredge-Lists
> Subject: Re: [Linux-PowerEdge] R720XD dead after IDRAC update trial
>
> Grzegorz,
>
> I've had a motherboard replacement needed due to iDRAC updates before.
> It's pretty frustrating.
>
> The only "emergency" procedure you might try:
>
> - disconnect power cords to PSUs
> - press and HOLD the power button to "drain the Flea power" (i presume
> this is a capacitor store residuals?)
>    Hold for 30 seconds
> - reconnect PSUs to power
> - power on and enable CAPS LOCK, SCROLL LOCK and NUM LOCK (may not be able
> to do immediately)
>   This *MAY* require you get into the BIOS "Setup" menu (<F2>) (which you
> indicate seems unlikely)
> - Press <ALT><E> , <ALT><F>, <ALT><B>
>   I can only imagine this stands for "Emergency F*ing Boot"
>
> If you are lucky, then the system will be reset.  If not, you might want
> to give up and have the Motherboard replaced (sigh)
>
> Ref:
>
> http://en.community.dell.com/techcenter/systems-management/w/wiki/3464.troubleshooting-idrac6-issues
>
> Good Luck,
> --stephen
>
>
>
> --
> Stephen Dowdy  -  Systems Administrator  -  NCAR/RAL
> 303.497.2869   -  [email protected]        -
> http://www.ral.ucar.edu/~sdowdy/
>
> _______________________________________________
> Linux-PowerEdge mailing list
> [email protected]
> https://lists.us.dell.com/mailman/listinfo/linux-poweredge
>

_______________________________________________
Linux-PowerEdge mailing list
[email protected]
https://lists.us.dell.com/mailman/listinfo/linux-poweredge
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.