Re: OMSA 8.3.0 not starting or segfaulting

"Dietrich, Stefan" <[email protected]>
Newsgroups gmane.linux.hardware.dell.poweredge
Message-ID <[email protected]>
Hi Souvik,

sorry, I forgot to mention, that this workaround is already deployed.

It is also very strange, that I am seeing this issue not on all machines.
Other machines with the same hardware and OS release are not having any issues with OMSA.

Regards,
Stefan

> Dell - Internal Use - Confidential
> Hi,
> 
> If Customer installs OMSA 8.3 in an unsupported OS, it might fail because of
> NVMe implementation. But, you can suppress loading NVMe library by using the
> following steps to avoid any crash.
> 
> Please do the following steps for disabling psrvil which is required for
> detecting NVMe Devices:
> 
> 1.       To stop all the services, please execute the command -
> srvadmin-services.sh stop
> 
> 2.       Go to /opt/dell/srvadmin/etc/srvadmin-storage/ directory
> 
> 3.       Open stsvc.ini file
> 
> 4.       Please comment the line - vil7=dsm_sm_psrvil. For commenting it out,
> you need to write ";" and one space before the statement, like ";
> vil7=dsm_sm_psrvil"
> 
> 5.       Save and close stsvc.ini file
> 
> 6.       To start all the services, please execute the command -
> srvadmin-services.sh start
> 
> It will stop loading psrvil library and OMSS should work fine.
> 
> Note: After commenting out psrvil library in stsvc.ini file, NO NVMe devices
> will get detected by OMSA
> 
> Thanks
> Souvik
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.