ibln() fails on Agilent 82357a

Dirk Niggemann <[email protected]>
Newsgroups gmane.linux.hardware.gpib.general
Message-ID <CAKrfojgqO01QxpyUZw3R7_WqBcNhdMTQeQ-n4G_+Y=0PA5iEFg@mail.gmail.com>
It looks like the Agilent 82357a has the same issue as some of Measurement
Computing cb7210.2 chips (even though it purports to e tms9914 internally)
and can't read the state of the NDAC line unless addressed to talk.
There was a simple one-line patch published by  Bernhard Heibler in 2004 on
this list that still applies today.

Adding the single line to add a MTA command in listenerFound in
ibFindLstn.c resolves the issue.

Can we make this either the standard behaviour or add some kind of option
in gpib.conf to enable the alternate behaviour?

For my application, autodiscovery would be very useful.

Regards,

Dirk