Re: "MPH_DEACTIVATE_IND" message.... (now with single port HFC board)
Karsten Keil <[email protected]>
| Newsgroups | gmane.linux.isdn.i4l.user |
|---|---|
| Message-ID | <[email protected]> |
Am 25.03.2014 10:07, schrieb fabio antonini: > Hi Doug > I have a scenario not far from yours and I'm facing the same problem. > I have a 4 channels cologne evalboard based on XHFC_4SU > > ~ # misdn_info > > Found 4 ports > Port 0 'XHFC.1': TE/NT-mode BRI S/T (for phone lines & phones) > 2 B-channels: 1-2 > B-protocols: RAW HDLC X75slp L2:DSP > L2:DSPHDLC > -------- > Port 1 'XHFC.2': TE/NT-mode BRI S/T (for phone lines & phones) > 2 B-channels: 1-2 > B-protocols: RAW HDLC X75slp L2:DSP > L2:DSPHDLC > -------- > Port 2 'XHFC.3': TE/NT-mode BRI S/T (for phone lines & phones) > 2 B-channels: 1-2 > B-protocols: RAW HDLC X75slp L2:DSP > L2:DSPHDLC > -------- > Port 3 'XHFC.4': TE/NT-mode BRI S/T (for phone lines & phones) > 2 B-channels: 1-2 > B-protocols: RAW HDLC X75slp L2:DSP > L2:DSPHDLC > > I have connected the first channel (TE mode) to an external equipment > (working fine for sure) configured as NT. > Does this be a P2P or P2MP type of line ? misdntestcon only works for P2MP lines. You should try misdntestlayer3 -P for P2P lines. Karsten