FW diag is broken?

Grant Grundler <[email protected]>
Newsgroups gmane.linux.ports.hppa
Message-ID <[email protected]>
Hi,
gsyprf11.external.hp.com is having problems and the latest manifestation
is this very odd output from the console when trying to netboot the
PF_CHAW4350.frm in order to update firmware:

Main Menu: Enter command or menu > bo lan
Interact with IPL (Y, N, or Cancel)?> n

Booting... 
Network Station Address 00306e-2661a3
System IP Address 192.6.38.61
Server IP Address 192.6.38.60

Boot IO Dependent Code (IODC) revision 2

IPL error: bad LIF magic.

************* SYSTEM ALERT **************
SYSTEM NAME: rp2470c
DATE: 04/02/2007 TIME: 04:21:21
ALERT LEVEL: 6 = Boot possible, pending failure - action required

REASON FOR ALERT
SOURCE: 8 = I/O 
SOURCE DETAIL: 6 = disk   SOURCE ID: 0
PROBLEM DETAIL: 0 = no problem detail

LEDs:  RUN      ATTENTION     FAULT     REMOTE     POWER
       FLASH    FLASH         ON        ON         ON
LED State: Boot Failed.  Running non-OS code.  Non-critical error detected.
Check Chassis and Console Logs for error messages.

0x00000060860010B0 00000000 00000000 - type  0 = Data Field Unused
0x58000860860010B0 00006B03 02041515 - type 11 = Timestamp 04/02/2007 04:21:21
A: ack read of this entry - X: Disable all future alert messages
Anything else skip redisplay the log entry
->Choice:Timeout!
*****************************************

************* SYSTEM ALERT **************
SYSTEM NAME: rp2470c
DATE: 04/02/2007 TIME: 04:21:22
ALERT LEVEL: 6 = Boot possible, pending failure - action required

REASON FOR ALERT
SOURCE: 8 = I/O 
SOURCE DETAIL: 6 = disk   SOURCE ID: 0
PROBLEM DETAIL: 0 = no problem detail

LEDs:  RUN      ATTENTION     FAULT     REMOTE     POWER
       FLASH    FLASH         ON        ON         ON
LED State: Boot Failed.  Running non-OS code.  Non-critical error detected.
Check Chassis and Console Logs for error messages.

0x00000060860014F0 00000000 00000000 - type  0 = Data Field Unused
0x58000860860014F0 00006B03 02041516 - type 11 = Timestamp 04/02/2007 04:21:22
A: ack read of this entry - X: Disable all future alert messages
Anything else skip redisplay the log entry
->Choice:X
*****************************************

CAUTION: System Alerts have been disabled. This will re-enable with 
a re-boot or power-on of the system. To re-enable system alerts now, you
may use the AC (Alert Display Configuration) command.

************* SYSTEM ALERT **************
Alert messages are now disabled. Enter Commands Interface AC command 
to enable them again
*****************************************


------------------------------- cut here --------------------------

The firmware update image should be fine...both copies I have are the same.
I get the same error when trying to boot from disk - and I'm obviously
trying to boot from LAN above, not disk.

So I have to wonder if this is really a RAM HW failure that the powerup
selftests are not catching. Or maybe some other HW failure? Can anyone
make sense of the "SOURCE DETAIL: 6 = disk" when booting from network?


thanks,
grant
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.