Re: [RFC v2 0/5] md/raid1: introduce a new sync action to repair badblocks

Zheng Qixing <[email protected]>
Newsgroups gmane.linux.raid,gmane.linux.kernel
Message-ID <[email protected]>
resend..

在 2026/2/4 0:31, Christoph Hellwig 写道:
> On Tue, Feb 03, 2026 at 04:08:23PM +0800, Zheng Qixing wrote:
>> Hi,
>>
>> 在 2026/2/3 15:31, Christoph Hellwig 写道:
>>> Just curious, but what kind of devices do you see that have
>>> permanent bad blocks at a fixed location that are not fixed by
>>> rewriting the sector?
>> The bad_blocks entries record sectors where I/O failed, which
>> indicates that the device-internal remapping did not succeed
>> at that time.
>>
>> `rectify` does not assume a permanently bad or fixed LBA. Its
>> purpose is to trigger an additional rewrite, giving the underlying
>> device (e.g. FTL or firmware) another opportunity to perform its
>> own remapping.
> Well, what devices do you see where writes fail, but rewrites
> fix them?

I understand your concerns, but I do not have a concrete example tied
to a specific device model...

The intent here is to provide an additional rewrite opportunity, which
allows the write path to be exercised again and gives the underlying
device or stack a chance to recover or remap the affected range.

For remote storage devices, I/O may fail due to network or transport
issues. If the final attempt fails, MD can record the affected range in
bad_blocks. This behavior does not appear to be tied to a specific
device model.

For local storage, some controllers may have limitations or corner cases
in their remapping mechanisms. In such cases, a sector that could
potentially be recovered may be marked as bad, leaving no opportunity
for a subsequent successful rewrite.
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.