RE: Adding a disk to a RAID array
"Stewart M. Ives" <[email protected]>
| Newsgroups | gmane.linux.redhat.release.enigma |
|---|---|
| Message-ID | <[email protected]> |
Liz, see questions below. stew [email protected] wrote: > I am not sure where to start so I will just jump right in. Up until > last week I had the manual for the SCSI card in my hand and now it has > managed to disappear. I am still looking for it, although I have > found a generic one from Adaptec that I have printed out and will go > through. Hopefully I will be able to find out what I need to know > concerning the hardware recognition of a new drive in the array. > > Hardware info: > DPT (bought out by Adaptec) PM2654 I20 BIOS SmartRAID V controller > card, firmware updated last April > 3 SCSI Hard drives 36gb Segate > > Here's the problem: > > I have a SCSI hardware RAID array of 3 drives. Space is running out Liz: You only show a single drive in your partition table below. Please provide a copy of your /proc/mdstat file for review. > on the data partition of the array and I need to add another 36gb > drive to the array. I think that all I need to do for the drive to be > seen by the hardware is to install the drive and boot up however, I > am still looking in to that. Here is the partition information: > start end mgb part type mounted > /dev/sda > - sda1 1 9 71 ext3 boot > - sda2 10 270 2047 Linux-swap > - sda3 271 336 518 ext3 tmp > - sda4 337 8924 67366 Extended > - sda5 337 859 4103 ext3 > - sda6 860 8924 6324 ext3 data > > I want to add the new drive space to the end of sda6 and into the > mounted data partition but I have not been able to find out any > information on how to do this. I have looked through a stack of What RAID level are you running or think you are running?? > books, asked those in the "know" here at work and no one seems to be > able to tell me how to do it. I know that I will have to back every > thing up in the data partition before doing this. I also know that I > have to do something in fdisk. I once did something like this to a > non RAIDed Alpha Ultrex system about 6yrs ago but have no idea of how > to proceeded here. I am trying not to have to reinstall the entire > system just to install a new drive. > > Assistance is greatly appreciated. > > Elizabeth R. E. Martin > Network Support Specialist > UT-Houston Medical School --- Outgoing SofTEC USA mail is certified Virus Free. Checked by AVG anti-virus system (http://www.grisoft.com). Version: 6.0.461 / Virus Database: 260 - Release Date: 3/10/2003