Re: 3Ware-controller-problem

Jason L Tibbitts III <[email protected]>
Newsgroups gmane.linux.redhat.release.enigma
Message-ID <[email protected]>
>>>>> "AR" == Andreas Rittershofer <[email protected]> writes:

AR> Today there was a power loss and now the array is degraded, one
AR> disk is "Not in Service". Remove disks does nothing, Add disk and
AR> Rebuild Array are giving error messages.

This really seems like a 3ware problem and not a Linux problem,
especially if you're doing these operations from the 3ware BIOS
(which you should of course try if you haven't).  Perhaps you should
talk to 3ware.

In any case, this happened to me recently with one of my 3ware
controllers (an old 6800).  In my case, the drive really was "not in
service"; it wouldn't even spin up.  Can't blame the controller for
that.

 - J<