Re: scsi tape drive troubles

Andreas Schindler <[email protected]>
Newsgroups gmane.linux.suse.sparc
Organization Alpha Zero One Computersysteme GmbH
Message-ID <[email protected]>
> >>>esp0: target 0 [period 100ns offset 15 10.00MHz FAST SCSI-II]
> >>>scsi : aborting command due to timeout : pid 35, scsi0, channel 0, id
> 0,
> lun 0 Request Sense 00 00 00 40 00
> >>>esp0: Aborting command
> >>>esp0: dumping state
> >>>esp0: dma -- cond_reg<a6400310> addr<c004498c>
> >>>esp0: SW [sreg<11> sstep<01> ireg<10>]
> >>>esp0: HW reread [sreg<01> sstep<c9> ireg<00>]
> >>>esp0: current command [tgt<00> lun<00> pphase<CLUELESS> cphase<DATAIN>]
> >>>esp0: disconnected
> >>>SCSI host 0 abort (pid 35) timed out - resetting
> >>>SCSI bus is being reset for host 0 channel 0.
> >>>esp0: Resetting scsi bus
> >>>esp0: Gross error sreg=40
> >>>esp0: SCSI bus reset interrupt
> SCSI device sda: 8498506 512-byte hdwr sectors (4351 MB)
> Partition check:
>  sda: sda1 sda2 sda3 sda4
> >>>esp0: AIEEE wide msg received and not HME.
> >>>esp0: hoping for msgout
> SCSI device sdb: 8813870 512-byte hdwr sectors (4513 MB)
>  sdb: sdb1 sdb3
> esp1: target 0 [period 100ns offset 15 20.00MHz FAST-WIDE SCSI-II]
> SCSI device sdc: 8388316 512-byte hdwr sectors (4295 MB)
>  sdc: sdc1 sdc3
> esp1: target 1 [period 100ns offset 15 20.00MHz FAST-WIDE SCSI-II]
> SCSI device sdd: 8388316 512-byte hdwr sectors (4295 MB)
>  sdd: sdd1 sdd3
> 
> etc..

This looks pretty much like a scsi bis error. I suggest you check these items
(in this order):

- tape set to a known unused scsi target i.d. (usually 4,5 or 6)

- proper termination of the external scsi bus. In particular, if you are using
  wide scsi disks along with a norrow scsi tape drive, the following
conditions
  must meet:
	- wide devices located near to the host adapter.
	- wide/narrow converter must have built in terminator for the upper 8 bits.
	- wide scsi cable should not exceed 0.5 meters
	- narrow cable between wide devices an tape should not exceed 0.5 meters.
  please note: the restrictive cable length requirements are due to the
               mixed mode (narror/small).

Good look, Your's Andreas
-- 

Dr. Andreas G. Schindler        c/o Alpha Zero One Computersysteme GmbH
[email protected]                Frankfurter Str. 141, D-63303 Dreieich
Tel +49 6103 57187 21           Germany

-- 
To unsubscribe, e-mail: [email protected]
For additional commands, e-mail: [email protected]
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.