Re: smart Airflow_Temperature_Cel attribute value on Micron RealSSD
Janardhan Molumuri <[email protected]>
| Newsgroups | gmane.linux.utilities.smartmontools |
|---|---|
| Message-ID | <CAE3V+3M2tPSpbVFX1oz7N2V5uZh71v3ReYfOL-5VRhRybp5g5A@mail.gmail.com> |
I found that the new disk firmware had fixed the SMART reporting and now it reports normalized values :) thanks for your assistance here, Christian. Janny On Sat, Jul 19, 2014 at 7:21 AM, Christian Franke < [email protected]> wrote: > Janardhan Molumuri wrote: > >> I should have clarified it, i meant smartctl -H ( --health) doesn't have >> an easy way to ignore some attributes. e.g. in this case 190. >> >> > There is not option specific for this rare use case (broken controller > firmware, bogus drive temperature attribute). > Normally -H does not check the attributes but simply prints boolean SMART > RETURN STATUS info from the drive. > > Try "-v 190,raw48:v" option as a workaround. It prints the VALUE field as > RAW and should suppress threshold check for attribute 190. > If this works, you could add a local drive database entry to > /etc/smart_drivedb.h, see -B option on smartctl man page. > > Thanks > Christian > > -- -- JNR ------------------------------------------------------------------------------ Want fast and easy access to all the code in your enterprise? Index and search up to 200,000 lines of code with a free copy of Black Duck Code Sight - the same software that powers the world's largest code search on Ohloh, the Black Duck Open Hub! Try it now. http://p.sf.net/sfu/bds _______________________________________________ Smartmontools-support mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/smartmontools-support