Pending Sectors, during LONG test
Larry Rosenman <[email protected]>
| Newsgroups | gmane.linux.utilities.smartmontools |
|---|---|
| Message-ID | <[email protected]> |
The last 2 times (If I recall correctly), I've gotten email from SmartD
(FreeBSD 11) with complaints about the following 2 counters:
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always
- 8
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age
Offline - 8
Once the test completes, they seem(!) to go away.
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining
LifeTime(hours) LBA_of_first_error
# 1 Extended offline Self-test routine in progress 90% 20538
-
Do I have an issue?
Full smartctl -a:
borg.lerctr.org /home/ler $ sudo smartctl -a /dev/ada4
smartctl 6.3 2014-07-26 r3976 [FreeBSD 11.0-CURRENT amd64] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke,
www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda Green (AF)
Device Model: ST2000DL003-9VT166
Serial Number: 5YDA1R5W
LU WWN Device Id: 5 000c50 053875d86
Firmware Version: CC32
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 5900 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Wed Feb 11 11:56:11 2015 CST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 249) Self-test routine in progress...
90% of test remaining.
Total time to complete Offline
data collection: ( 623) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 344) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x30b7) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE
UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 109 087 006 Pre-fail Always
- 21689208
3 Spin_Up_Time 0x0003 075 075 000 Pre-fail Always
- 0
4 Start_Stop_Count 0x0032 100 100 020 Old_age Always
- 67
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always
- 0
7 Seek_Error_Rate 0x000f 083 060 030 Pre-fail Always
- 9029529080
9 Power_On_Hours 0x0032 077 077 000 Old_age Always
- 20538
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always
- 0
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always
- 67
183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always
- 0
184 End-to-End_Error 0x0032 100 100 099 Old_age Always
- 0
187 Reported_Uncorrect 0x0032 042 042 000 Old_age Always
- 58
188 Command_Timeout 0x0032 100 097 000 Old_age Always
- 60
189 High_Fly_Writes 0x003a 100 100 000 Old_age Always
- 0
190 Airflow_Temperature_Cel 0x0022 076 064 045 Old_age Always
- 24 (Min/Max 21/33)
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always
- 0
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always
- 57
193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always
- 67
194 Temperature_Celsius 0x0022 024 040 000 Old_age Always
- 24 (0 20 0 0 0)
195 Hardware_ECC_Recovered 0x001a 015 004 000 Old_age Always
- 21689208
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always
- 8
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age
Offline - 8
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always
- 0
240 Head_Flying_Hours 0x0000 100 253 000 Old_age
Offline - 20537 (132 184 0)
241 Total_LBAs_Written 0x0000 100 253 000 Old_age
Offline - 1746396844
242 Total_LBAs_Read 0x0000 100 253 000 Old_age
Offline - 1758546700
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining
LifeTime(hours) LBA_of_first_error
# 1 Extended offline Self-test routine in progress 90% 20538
-
# 2 Short offline Completed without error 00% 20512
-
# 3 Short offline Completed without error 00% 20488
-
# 4 Short offline Completed without error 00% 20464
-
# 5 Short offline Completed without error 00% 20440
-
# 6 Short offline Completed without error 00% 20416
-
# 7 Short offline Completed without error 00% 20392
-
# 8 Short offline Completed without error 00% 20368
-
# 9 Extended offline Completed without error 00% 20367
-
#10 Short offline Completed without error 00% 20344
-
#11 Short offline Completed without error 00% 20320
-
#12 Short offline Completed without error 00% 20296
-
#13 Short offline Completed without error 00% 20272
-
#14 Short offline Completed without error 00% 20248
-
#15 Short offline Completed without error 00% 20224
-
#16 Short offline Completed without error 00% 20200
-
#17 Extended offline Completed without error 00% 20199
-
#18 Short offline Completed without error 00% 20176
-
#19 Short offline Completed without error 00% 20152
-
#20 Short offline Completed without error 00% 20128
-
#21 Short offline Completed without error 00% 20104
-
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute
delay.
borg.lerctr.org /home/ler $
--
Larry Rosenman http://www.lerctr.org/~ler
Phone: +1 214-642-9640 E-Mail: [email protected]
US Mail: 108 Turvey Cove, Hutto, TX 78634-5688
------------------------------------------------------------------------------
Dive into the World of Parallel Programming. The Go Parallel Website,
sponsored by Intel and developed in partnership with Slashdot Media, is your
hub for all things parallel software development, from weekly thought
leadership blogs to news, videos, case studies, tutorials and more. Take a
look and join the conversation now. http://goparallel.sourceforge.net/