[Smartmontools-databas e] Add support for INNODISK 2.5” SATA SSD 3ME

Arinci Simone <[email protected]> Thu, 14 Jan 2016 16:35:15 +0000
Newsgroups gmane.linux.utilities.smartmontools
Message-ID <8D96E5AEF603B140B8A67924EEAA31BEB9DD8A3D@MP-2KS-XMX01.fincantieri.it>
See attached SMARTCTL report for the SDD in object.
The product is described here:
http://www.innodisk.com/Product/ProductDetail.aspx?SUQwMT0wMDEmSUQwMj0zMzk2Yjk5Yi00ZTM1LTRlNjctYWZjYS0yNGFiMWYzY2M2MzcmSUQwMz0mSUQ9ODc5NDZkMjEtYTE2OS00YTBhLThjZjgtMzdiZDZlN2M0MjJmJmRmbF9JRD0wMDE%3D

Some smart attributes are unknown for SMARTCTL. Using the SMART utilities "iSmart" (developed by Jactron, seems an Innodisk parner company) it is possible to obtain an export with the smart attributes named, see below:
Model	2.5" SATA SSD 3ME                       	119.24 GB
Firmware	S140714 
Serial Number	
09	Power On Hours	23	0200646417000000000000
0C	Power Cycle Count	15	020064640F000000000000
AD	Erase Count Max.	23	0200646409001700000000
AD	Erase Count Avg.	9	0200646409001700000000
A9	Reman Life	0	0000000000000000000000
C2	Temperature	0	0000000000000000000000
E5	Flash ID	0	0200646498DE9493765000
EB	Later Bad Block	0	0200640000000000000000
EB	Read Block	0	0200640000000000000000
EB	Write Block	0	0200640000000000000000
EB	Erase Block	0	0200640000000000000000
EC	Unstable Power Count	0	0200646400000000000000

>From a quick analysys and comparison with the SMARTCTL report it seems to me that attributes 16#AD (173 dec) contains a couple of parameter, one in the lower word the other in the upper word.
Something similar, probably, also for 16#EB attribute.

Jactron ISMART is available here:
http://www.jactron.co.uk/s-m-a-r-t-monitoring-tools/

Please add to SMARTMONTOOLS database.

Have a nice day, 
Simone Arinci

------------------------------------------------------------------------------
Site24x7 APM Insight: Get Deep Visibility into Application Performance
APM + Mobile APM + RUM: Monitor 3 App instances at just $35/Month
Monitor end-to-end web transactions and take corrective actions now
Troubleshoot faster and improve end-user experience. Signup Now!
http://pubads.g.doubleclick.net/gampad/clk?id=267308311&iu=/4140

_______________________________________________
Smartmontools-support mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/smartmontools-support
REP_INNODISK_3ME.TXT (text/plain, 5.8 KB)
smartctl 6.3 2014-07-26 r3976 [i686-w64-mingw32-win7] (sf-6.3-1)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     2.5" SATA SSD 3ME
Serial Number:    
Firmware Version: S140714
User Capacity:    128,035,676,160 bytes [128 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Form Factor:      2.5 inches
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-2 (minor revision not indicated)
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Tue Jan 12 14:27:54 2016 PST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM feature is:   Unavailable
Rd look-ahead is: Enabled
Write cache is:   Enabled
ATA Security is:  Disabled, frozen [SEC2]
Read SCT Status failed: Input/output error
Wt Cache Reorder: Unknown (SCT Feature Control command failed)

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00)	Offline data collection activity
					was never started.
					Auto Offline Data Collection: Disabled.
Total time to complete Offline 
data collection: 		(   32) seconds.
Offline data collection
capabilities: 			 (0x00) 	Offline data collection not supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x00)	Error logging NOT supported.
					General Purpose Logging supported.
SCT capabilities: 	       (0x0039)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     ------   000   000   000    -    0
  2 Throughput_Performance  ------   000   000   000    -    0
  3 Spin_Up_Time            ------   000   000   000    -    0
  5 Reallocated_Sector_Ct   -O----   100   100   000    -    0
  7 Unknown_SSD_Attribute   ------   000   000   000    -    0
  8 Unknown_SSD_Attribute   ------   000   000   000    -    0
  9 Power_On_Hours          -O----   100   100   000    -    23
 10 Unknown_SSD_Attribute   ------   000   000   000    -    0
 12 Power_Cycle_Count       -O----   100   100   000    -    15
168 Unknown_Attribute       ------   000   000   000    -    0
169 Unknown_Attribute       ------   000   000   000    -    0
175 Program_Fail_Count_Chip ------   000   000   000    -    0
192 Power-Off_Retract_Count ------   000   000   000    -    0
  1 Raw_Read_Error_Rate     ------   000   000   000    -    2199023255552
197 Current_Pending_Sector  ------   000   000   000    -    0
240 Unknown_SSD_Attribute   ------   000   000   000    -    0
225 Unknown_SSD_Attribute   ------   000   000   000    -    0
170 Unknown_Attribute       PO----   100   100   ---    -    2359296
173 Unknown_Attribute       -O----   100   100   ---    -    1507337
229 Unknown_Attribute       -O----   100   100   ---    -    88470212370072
236 Unknown_Attribute       -O----   100   100   ---    -    0
235 Unknown_Attribute       -O----   100   000   ---    -    0
176 Erase_Fail_Count_Chip   ------   100   000   ---    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

Read SMART Log Directory failed: Input/output error

General Purpose Log Directory Version 1
Address    Access  R/W   Size  Description
0x00       GPL     R/O      1  Log Directory
0x03       GPL     R/O     64  Ext. Comprehensive SMART error log
0x07       GPL     R/O      1  Extended self-test log
0x10       GPL     R/O      1  NCQ Command Error log
0x11       GPL     R/O      1  SATA Phy Event Counters
0x80-0x9f  GPL     R/W     16  Host vendor specific log
0xe0       GPL     R/W      1  SCT Command/Status
0xe1       GPL     R/W      1  SCT Data Transfer

ATA_READ_LOG_EXT (addr=0x03:0x00, page=0, n=1) failed: Input/output error
Read SMART Extended Comprehensive Error Log failed

SMART Error Log not supported

ATA_READ_LOG_EXT (addr=0x07:0x00, page=0, n=1) failed: Input/output error
Read SMART Extended Self-test Log failed

SMART Self-test Log not supported

Selective Self-tests/Logging not supported

Read SCT Status failed: Input/output error

Read SCT Status failed: Input/output error
SCT (Get) Error Recovery Control command failed

Device Statistics (GP Log 0x04) not supported

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x0001  2           25  Command failed due to ICRC error
0x0003  2            0  R_ERR response for device-to-host data FIS
0x0004  2            0  R_ERR response for host-to-device data FIS
0x0006  2            0  R_ERR response for device-to-host non-data FIS
0x0007  2            0  R_ERR response for host-to-device non-data FIS
0x0008  2            0  Device-to-host non-data FIS retries
0x0009  4            0  Transition from drive PhyRdy to drive PhyNRdy
0x000a  4           20  Device-to-host register FISes sent due to a COMRESET
0x000f  2            0  R_ERR response for host-to-device data FIS, CRC
0x0010  2            0  R_ERR response for host-to-device data FIS, non-CRC
0x0012  2            0  R_ERR response for host-to-device non-data FIS, CRC
0x0013  2            0  R_ERR response for host-to-device non-data FIS, non-CRC