Re: new drivedb.h incompatible?

Christian Franke <[email protected]> Tue, 3 May 2016 06:47:56 +0200
Newsgroups gmane.linux.utilities.smartmontools
Message-ID <[email protected]>
Reinoud Koornstra wrote:
> ...
> Better now:
>
> May  2 20:17:12 router-dev smartd[15615]: smartd 6.5 2016-05-01 r4315 [x86_64-linux-4.4.5] (local build)
> ...
> May  2 20:17:12 router-dev smartd[15615]: Device: /dev/sda [SAT], SMART Usage Attribute: 194 Temperature_Celsius changed from 117 to 116
> May  2 20:17:12 router-dev smartd[15615]: Device: /dev/sdb [SAT], SMART Usage Attribute: 194 Temperature_Celsius changed from 71 to 70

Note that these are the normalized values of the temperatures attribute 
(the latter might mean 100-Celsius).
See:
https://www.smartmontools.org/wiki/FAQ#Whyismydisktemperaturesreportedbysmartdas150Celsius

Try '-I 194 -W 4' in smartd.conf to suppress above output and track 
temperature changes >= 4 degrees.

Thanks,
Christian


------------------------------------------------------------------------------