Re: weird 194 Temperature_Celsius in smartctl csv dump

Christian Franke <[email protected]> Tue, 20 Dec 2016 19:32:11 +0100
Newsgroups gmane.linux.utilities.smartmontools
Message-ID <[email protected]>
Adrian Sandu wrote:
> So,
>
> I have a WD Red Pro 6TB model WDC WD6002FFWX-68TZ4N0 ...
>
> smartctl -a says
> 194 Temperature_Celsius     0x0002   130   130   000    Old_age   Always       -       46 (Min/Max 25/51)
>
> smartd is ran with  -A /var/lib/smartd/ , so in /var/lib/smartd/WDC_WD6002FFWX_68TZ4N0-....ata.csv I see something like:
> 2016-12-20 17:01:33;   .....194;133;219044970541; ......
>
> Anyone can help me decode this values in something more usable ?

219044970541 Decimal = 33 00 19 00 2d Hex -> max 41, min 25, current 45

See also:
https://sourceforge.net/p/smartmontools/mailman/message/35136816/

Thanks,
Christian


------------------------------------------------------------------------------
Developer Access Program for Intel Xeon Phi Processors
Access to Intel Xeon Phi processor-based developer platforms.
With one year of Intel Parallel Studio XE.
Training and support from Colfax.
Order your platform today.http://sdm.link/intel