Re: how to access a global variable defined in wiretap(new format) from epan/dissector

"Ravi Kondamuru" <[email protected]>
Newsgroups gmane.network.ethereal.devel
Message-ID <[email protected]>
The best way in my opinion will be to pass such infromation through the
pseudo_header defined for your format.

Will this be an entire trace file specific property or one that varies for
each packet in the file?

Thanks,
Ravi.

On 5/24/06, Raman Singla <[email protected]> wrote:
>
>  hi
> I have written a new capture format(dec-trace) which reads from saved file
> & corresponding dissector.
>
> Since dec-trace can be in either of big/little format. so i want to pass
> this global variable from wiretap (where it will read endian type)  to
> epan/dissector (where value of this variable will be read by dissector &
> based on that decoding will take place).
>
> It was workign on linux platform very well,
> but as i building the same on Windows platform using msvc it is showing
> linking problem. unresolved reference.
>
> /******************** I m not sure but this could be the reason
> ***********/
> When i tried to go in deep it could be b'cos of dissector.lib. since
> linker tries to resolves it within dissector.lib.
>
> /**************************************************************************************/
>
> what could be the way access global variable defined in wiretap ?
>
> regards,
> Raman
> Ext - 1667
>
> _______________________________________________
> Ethereal-dev mailing list
> [email protected]
> http://www.ethereal.com/mailman/listinfo/ethereal-dev
>
>
>