Re: Fcp sizes and time

Matthew Toseland <toad-EI5O+8PHWbJeeLb3ft/[email protected]>
Newsgroups gmane.network.freenet.technical
Message-ID <[email protected]>
On Wednesday 13 February 2008 21:44, Jerome Flesch wrote:
> I commited a patch into the node to make it possible to ask for expected 
data 
> types with FCP.
> See http://wiki.freenetproject.org/FCP2p0GetConfig , 
> http://wiki.freenetproject.org/FCP2p0ConfigData .
> 
> I hope it will help you (anyway it will help me :)
> 
> For periods, I can't make the data type more specific than "string" at the 
> moment, sorrry.
> 
> Currently, I'm wondering if it would also be a good idea to convert all the 
> values into basic units (-> in bytes) and let the client apps displays it in 
> a more user-friendly way ? (I'm not really sure how the client would handle 
> values like '1025' ...)

Exactly, there's a reason why we keep the original string. If the user wants 
12 GiB then we should remember that it's 12GiB and not 12884901888 bytes.
> 
> 
> > Jerome Flesch schrieb:
> > >> Hi,
> > >>
> > >> I have a question regarding byte sizes in Fcp. Along with some requests
> > >> sizes are passed as 1G or 1000K.
> > >
> > > I would be interrested to know where you saw that. From what I know, FCP
> > > always provide/need sizes/times in bytes/seconds (except for things
> > > related to the node config, see below).
> >
> > ConfigData
> >     current.node.outputBandwidthLimit=12K
> >     current.node.storeSize=1G
> >     (...)
> > EndMessage
> >
> > >> Quite obvious what it's about but
> > >> nevertheless it is not documented.
> > >>
> > >> Can I assume Fcp always uses kibs and values are always passed 
following
> > >> this patttern?
> > >>
> > >> -1 (not set)
> > >> n
> > >> n*1000 or (n)K
> > >> n*1.000.000 or (n)M
> > >> (...)
> > >>
> > >> The only time value (except from secs since epoch) I faced so far is 
one
> > >> I got in
> > >> response to GetConfig. It read '1HOUR'. Is there a similar pattern for
> > >> time values to rely on?
> > >
> > > This value comes directly from the node configuration, and node
> > > configuration is made to be human readable. Imo, that's the only reason
> > > why this time is not given in seconds.
> >
> > ConfigData
> >     default.logger.interval=1HOUR
> > EndMessage
> >
> >
> > To make these values adjustable by users I have to parse them.
> > So there should be a spec somewhere. It would be enough to give
> > me a pointer where to find it in freenets sources (still a bit lost
> > in there) and I'd happily add a page regarding Fcp types to the wiki.
> >
> >
> > Juergen
> >
> >
> >
> >
> >
> > _______________________________________________
> > Tech mailing list
> > [email protected]
> > http://emu.freenetproject.org/cgi-bin/mailman/listinfo/tech
> 
> 
> 
> -- 
> Jerome Flesch
>

_______________________________________________
Tech mailing list
[email protected]
http://emu.freenetproject.org/cgi-bin/mailman/listinfo/tech
signature.asc (application/pgp-signature, 189 B)