Re : verify connection to master agent

brisse <[email protected]>
Newsgroups gmane.network.net-snmp.user
Message-ID <[email protected]>
<!-- DIV {margin:0px} --Hi,

thanks for your reply. I looked at the snmpd.conf man page. 
As a result I added 
netsnmp_ds_set_int(NETSNMP_DS_APPLICATION_ID,
                NETSNMP_DS_AGENT_AGENTX_PING_INTERVAL,10);

in the initialization of my subagent. 

then I tried to stop my master (snmpd) and start it again. Then my subagent is not able to register again. I got the following error:

Error: Failed to connect to the agentx master agent: Unknown host (No such file or directory)

AgentX master agent failed to respond to ping.  Attempting to re-register.

Any ideas??




----- Message d'origine ----
De : Dave Shield  <[email protected]>
À : brisse <[email protected]>
Cc : [email protected]
Envoyé le : Lundi, 13 Mars 2006, 11h54mn 25s
Objet : Re: verify connection to master agent

On Thu, 2006-03-09 at 11:30 +0100, brisse wrote:
> I would like a mechanism to check the connection to
> the master agent. For example the master crashes and
> then up again. How can I make sure that my subagent
> reconnect properly to the master??? 

Please see the snmpd.conf(5) man page - in particular
the 'agentPingInterval' directive.


> Do I have to do
> these steps again: 
>     
> netsnmp_ds_set_boolean(NETSNMP_DS_APPLICATION_ID,NETSNMP_DS_AGENT_ROLE,1));
> init_agent("mySubAgentName");
> init_myMIB();;
> init_snmp("mySubAgentName");
> 
> then again my loop:
> agent_check_and_process(0);


Have a look at how  this directive is implemented - in particular,
follow the code through from 'agentx_reopen_session()' (in the file
mibgroup/agentx/subagent.c)

Dave