Antwort: Re: Re: Contained Sequences

[email protected]
Newsgroups gmane.network.net-snmp.user
Message-ID <OF75F5D944.83183708-ONC12571B6.005610F1-C12571B6.005671D0@rohde-schwarz.com>



No need to get tetchy, I was only asking...

Your explanation could well be correct, it was some time ago and not
something I was directly involved in.

I wouldn't be a particurlary good engineer if I accepted *everything* at
face value now, would I?

No offence intended, but my experience with academia has not always been
equitable. A good number of academic types have responded with "won't"
rather than "can't". I need to figure out which one applies here.

Between this "problem" and other problems, I am beginning to wonder if
selecting CMIP/CMISE would not have been preferrable...

Enjoy the rest of your day.



                                                                           
             "Dave Shield"                                                 
             <[email protected]                                             
             iv.ac.uk>                                                  An 
             Gesendet von:              "[email protected] 
             dave.shield@googl          m"                                 
             email.com                  <[email protected] 
                                        m>                                 
                                                                     Kopie 
             25.07.2006 17:24           [email protected] 
                                        et                                 
                                                                     Thema 
                                        Re: Re: Contained Sequences        
                                                                           
                                                                           
                                                                           
                                                                           
                                                                           
                                                                           




On 25/07/06, [email protected] wrote:
> Is that true? Or is it just not supported in Net-SNMP?

No - it's a fundamental part of SNMP.
You can *NOT* have a table-within-a-table

> I am pretty sure I have seen this done in other SNMP V2 agents, Wind
> River's built-in SNMP Agent in Tornado, for example. I am also pretty
sure
> that I have seen this supported in HP OpenView....

It is quite possible that particular management tools will take a pair
of parallel tables and *display* them as if one was within the other.
But it's not possible to *define* them as such - SNMP does not support
this.  Full Stop.

I can dig out chapter and verse if you don't believe me?

Dave



-------------------------------------------------------------------------
Take Surveys. Earn Cash. Influence the Future of IT
Join SourceForge.net's Techsay panel and you'll get the chance to share your
opinions on IT & business topics through brief surveys -- and earn cash
http://www.techsay.com/default.php?page=join.php&p=sourceforge&CID=DEVDEV
_______________________________________________
Net-snmp-users mailing list
[email protected]
Please see the following page to unsubscribe or change other options:
https://lists.sourceforge.net/lists/listinfo/net-snmp-users
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.