Re: Help required on net-snmp multiple varbind get-next generic error problem

"Dave Shield" <[email protected]>
Newsgroups gmane.network.net-snmp.user
Message-ID <[email protected]>
On 21/01/2008, srinivas pippiri <[email protected]> wrote:
>  I tried upgrading to 5.3.2 and still the problem remains.

>  But if i include more than one MIB object including the last MIB object of
> the table, we are getting the problem of Generic error.

I've just tried a similar query with one of the standard
iterator-based MIB tables,
and it works fine.   I'm more and more coming to the conclusion that this
is probably a bug in your particular MIB module, rather that the iterator
helper itself.


>                 In debug mode i have
> seen there is a big loop going on(say suppose if i include all the 6 MIB
> objects of the table get_next_data_point from our MIB module is getting
> called 28000 times).

How many rows are there in this table?
Note that the iterator helper is know to be relatively inefficient.
If you've got a large table, then you might be better off using one
of the other MIB helpers.

How are the underlying contents of the table stored and retrieved?
What do the 'get_first'/'get_next' hook routines look like?

Dave

-------------------------------------------------------------------------
This SF.net email is sponsored by: Microsoft
Defy all challenges. Microsoft(R) Visual Studio 2008.
http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/
_______________________________________________
Net-snmp-users mailing list
[email protected]
Please see the following page to unsubscribe or change other options:
https://lists.sourceforge.net/lists/listinfo/net-snmp-users
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.