Re: Help required on net-snmp multiple varbind get-next generic error problem

"Dave Shield" <[email protected]>
Newsgroups gmane.network.net-snmp.user
Message-ID <[email protected]>
On 22/01/2008, srinivas pippiri <[email protected]> wrote:
> The table contains 6 rows and i am using the standard MIB tables

What does "the standard MIB tables" mean?

> 1st case
> index is two dimensional say suppose (Mib1.1.1).
> Here i am performing the Get-Next on the last index for all the MIB objects
> in the table in multiple varbind. In this case it is returning Generic
> error. If i take the index out of range also the same error we are getting.

Please can you supply the *exact* requests you are trying
(including the actual OIDs).  I do not have the time to try and
guess this information from the descriptions you are providing.
A cut-n-paste transcript of a real testing session would be much clearer.



> Even if we take the out of range indexes also we are getting the correct
> response.

Same here.


> > How are the underlying contents of the table stored and retrieved?
> > What do the 'get_first'/'get_next' hook routines look like?

Could you please answer these questions.

Dave

-------------------------------------------------------------------------
This SF.net email is sponsored by: Microsoft
Defy all challenges. Microsoft(R) Visual Studio 2008.
http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/
_______________________________________________
Net-snmp-users mailing list
[email protected]
Please see the following page to unsubscribe or change other options:
https://lists.sourceforge.net/lists/listinfo/net-snmp-users
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.