Re: Is it possible to have write-only MIB item?
"Dave Shield" <[email protected]>
| Newsgroups | gmane.network.net-snmp.user |
|---|---|
| Message-ID | <[email protected]> |
[ First - *please* don't mail me privately, without copying
any responses to the mailing list. I don't have the time
or inclination to offer private, unpaid, SNMP consultancy.
Keep discussions to the list, where others can both learn
and offer advice. Thanks. ]
2008/6/16 Patel, Narendra - CS <[email protected]>:
> I am using Castle Rock "SNMPc WorkGroup Edition" program on PC Window
> platform for MIB browsing. To change (set) any MIB item I have to read
> (get) on GUI and change the value on the GUI and select Set button, so
> if I can not get can not set.
As I said - some management applications may not like an object
that cannot be read. But that's a limitation of the management tool,
not the SNMP protocol.
The simplest approach is to return a standard value for this object,
and document this behaviour within the MIB file. For example,
objects of type UCDErrorFix will always return 0. But the real
purpose of such objects is to SET a value of 1 to active that entry.
Dave
-------------------------------------------------------------------------