Re: why do we put .0 after sysUpTime OID?

Dave Shield <[email protected]>
Newsgroups gmane.network.net-snmp.user
Message-ID <[email protected]>
2009/4/16 acec acec <[email protected]>:
> I checked rfc1213 MIB definition, OID of sysUpTime is "1.3.6.1.2.1.1.3".

The OID of the MIB (scalar) *object* is .1.3.6.1.2.1.1.3
The OID of the (sole) *instance* of this MIB object is .1.3.6.1.2.1.1.3.0

Have a quick read up on how SNMP represents scalar instances.

Dave

------------------------------------------------------------------------------