RE: snmp.conf syntax

Michal Filka <[email protected]>
Newsgroups gmane.network.net-snmp.user
Message-ID <BEE650D2F88D74448AD3E613B0C6D4E5C447D056@STS-PRG-EXM1M1.sts.sitronics.com>
> The DisMan monitoring simply says "send a notification".
> It doesn't control where those notifications are sent, or what version
> they should be.
> That's the role of "trapsink" and similar.
> 
> If you configure the agent with "trapsink", then it will send v1 traps.
> If you configure the agent with "trap2sink", then it will send v2c traps.
> If you configure the agent with "informsink", then it will send v2c informs.

I read this in man pages:
notificationEvent ENAME NOTIFICATION [-n] [-i OID | -o OID ]* 
defines a notification event named ENAME. This can be triggered from a given monitor entry by specifying the option -e ENAME (see above). NOTIFICATION should be the OID of the NOTIFICATION-TYPE definition for the notification to be generated.

The question was if NOTIFICATION really has to be OID of NOTIFICATION-TYPE or if it is possible to somehow put TRAP-TYPE here (I have to use some SMIv1 mibs)
> 
Michal Filka

------------------------------------------------------------------------------
Let Crystal Reports handle the reporting - Free Crystal Reports 2008 30-Day 
trial. Simplify your report design, integration and deployment - and focus on 
what you do best, core application coding. Discover what's new with 
Crystal Reports now.  http://p.sf.net/sfu/bobj-july
_______________________________________________
Net-snmp-users mailing list
[email protected]
Please see the following page to unsubscribe or change other options:
https://lists.sourceforge.net/lists/listinfo/net-snmp-users
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.