Re: setEvent

Dave Shield <[email protected]>
Newsgroups gmane.network.net-snmp.user
Message-ID <[email protected]>
2009/8/25 Michal Filka <[email protected]>:
> I append value definition for completeness:
> test    OBJECT-TYPE
>                SYNTAX          Unsigned32
>                MAX-ACCESS      read-write
>                STATUS          current
>                DESCRIPTION     "description"
>        ::=     { control 2 }
>
> Is Unsigned32 type OK for setEvent?

What about the definition of "test2"?
  (which is the object that you specify in the setEvent line)

>  Is Unsigned32 type OK for setEvent?

Yes - that should be fine.

> It is handled in a dynamic module using netsnmp_register_ulong_instance function.

Hmmm... you should probably be registering test.0 (assuming this is a
scalar object)
Or else using "netsnmp_register_scalar"
And the monitor directive would be more efficient with the '-i'
option, if there's only
a single instance to be monitored.

Dave

------------------------------------------------------------------------------
Let Crystal Reports handle the reporting - Free Crystal Reports 2008 30-Day 
trial. Simplify your report design, integration and deployment - and focus on 
what you do best, core application coding. Discover what's new with 
Crystal Reports now.  http://p.sf.net/sfu/bobj-july
_______________________________________________
Net-snmp-users mailing list
[email protected]
Please see the following page to unsubscribe or change other options:
https://lists.sourceforge.net/lists/listinfo/net-snmp-users
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.