Re: Event not Genrate
Mudassar <[email protected]>
| Newsgroups | gmane.network.net-snmp.user |
|---|---|
| Message-ID | <[email protected]> |
Hi, Thanks, its works after using -I instead of -u. Thanks. M -------- Original Message -------- Subject: Re: Event not Genrate From: Dave Shield <[email protected]> To: Mudassar <[email protected]> Cc: net-snmp users <[email protected]> Date: 11/30/2009 4:04 PM > 2009/11/26 Mudassar <[email protected]>: > >> I am trying to trigger an event on physical memory and add the following >> line in snmpd.conf, all other events are working perfect >> >> monitor -u _internal -r 2 "Low Physical Memory" -o hrMemorySize >> hrStorageUsed.1 > 1100000 >> > > Do the other events use the same "-u" user? > Given that this is a single-instance monitor, > it might be sensible to use the -I flag. > > If that doesn't work, then some more information about the > events that *do* work might be useful > > Dave > > ------------------------------------------------------------------------------ Let Crystal Reports handle the reporting - Free Crystal Reports 2008 30-Day trial. Simplify your report design, integration and deployment - and focus on what you do best, core application coding. Discover what's new with Crystal Reports now. http://p.sf.net/sfu/bobj-july _______________________________________________ Net-snmp-users mailing list [email protected] Please see the following page to unsubscribe or change other options: https://lists.sourceforge.net/lists/listinfo/net-snmp-users