Re: Event not Genrate

Mudassar <[email protected]>
Newsgroups gmane.network.net-snmp.user
Message-ID <[email protected]>
Hi,

Thanks, its works after using -I instead of -u.

Thanks.
M




-------- Original Message  --------
Subject: Re: Event not Genrate
From: Dave Shield <[email protected]>
To: Mudassar <[email protected]>
Cc: net-snmp users <[email protected]>
Date: 11/30/2009 4:04 PM
> 2009/11/26 Mudassar <[email protected]>:
>   
>> I am trying to trigger an event on physical memory and add the following
>> line in snmpd.conf, all other events are working perfect
>>
>> monitor -u _internal -r 2 "Low Physical Memory" -o hrMemorySize
>>     hrStorageUsed.1 > 1100000
>>     
>
> Do the other events use the same "-u" user?
> Given that this is a single-instance monitor,
>   it might be sensible to use the -I flag.
>
> If that doesn't work, then some more information about the
> events that *do* work might be useful
>
> Dave
>
>

------------------------------------------------------------------------------
Let Crystal Reports handle the reporting - Free Crystal Reports 2008 30-Day 