Re: sysObjectID still returns an incorrect value

Fulko Hew <[email protected]>
Newsgroups gmane.network.net-snmp.devel,gmane.network.net-snmp.user
Message-ID <[email protected]>
On Thu, Sep 16, 2010 at 12:31 PM, Wes Hardaker <
[email protected]> wrote:

> >>>>> On Wed, 15 Sep 2010 16:00:42 -0400, Fulko Hew <[email protected]>
> said:
>
> FH> WATCHER_MAX_SIZE | WATCHER_SIZE_IS_PTR | WATCHER_SIZE_UNIT_OIDS,
>
> FH> whereas the value passed in via sysObjectIDByteLength has already been
> FH> converted
> FH> into bytes.  so the above statement on line 339
> FH> should instead be:
>
> FH> WATCHER_MAX_SIZE | WATCHER_SIZE_IS_PTR
>
> Thanks for diving into the code to look at that.  I started to yesterday
> but got distracted.  After making the above change does it fix your
> problem?
>

Yes, It did for me.
I tested:

1/ Net-SNMP reporting its 'internally' defined sysObjectID
2/ a sysObjectID override in the snmpd.conf file.

Are there any other scenarios that I missed testing?

------------------------------------------------------------------------------
Start uncovering the many advantages of virtual appliances
and start using them to simplify application deployment and
accelerate your shift to cloud computing.
http://p.sf.net/sfu/novell-sfdev2dev

_______________________________________________
Net-snmp-coders mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/net-snmp-coders
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.