Fwd: Understanding mibs (out of range error)

Javier Barroso <[email protected]>
Newsgroups gmane.network.net-snmp.user
Message-ID <CAL5yMZQnvTEcC_oL0Fz9yt=1LG5-mffzHB9ApHr3kDRRNRo8xw@mail.gmail.com>
(Sorry if this mail arrive two times, I sent the same email before
than I was subscripted (and sorry to mail list moderator))

Hello,

Having http://www.circitor.fr/Mibs/Files/BLUEARC-TITAN-MIB.mib which
import mibs from
http://www.circitor.fr/Mibs/Files/BLUEARC-SERVER-MIB.mib

$ snmptranslate -m +BLUEARC-TITAN-MIB
.1.3.6.1.4.1.11096.6.2.1.2.1.2.1.2.3106234445.110.101.118.105.108.108.97

BLUEARC-TITAN-MIB::virtualVolumeTitanName.3106234445.110.101.118.105.108.108.97

$ snmptranslate -m +BLUEARC-TITAN-MIB
.1.3.6.1.4.1.11096.6.2.1.2.1.2.1.2.3106234445.111.101.118.105.108.108.97

.1.3.6.1.4.1.11096.6.2.1.2.1.2.1.2.3106234445.111.101.118.105.108.108.97:
Unknown Object Identifier (Index out of range: 111
(virtualVolumeTitanName))

This is triyng to monitorize volume from a Hitachi Storage.

Seems like the volume cannot start with a letter with ascii code
greater than 110

A volume with name "n" can be asked by snmpget but a volume with name "o" cannot

I can't find where is the issue with such mibs. I'am asking to hitachi too.

Can you help me to understand what is happening here ?

Thank you very much

------------------------------------------------------------------------------
Check out the vibrant tech community on one of the world's most
engaging tech sites, Slashdot.org! http://sdm.link/slashdot
_______________________________________________
Net-snmp-users mailing list
[email protected]
Please see the following page to unsubscribe or change other options:
https://lists.sourceforge.net/lists/listinfo/net-snmp-users
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.