Re: [f-nsp] Basic SNMP MIBs missing
Eldon Koyle <[email protected]>
| Newsgroups | gmane.network.nsp.foundry |
|---|---|
| Message-ID | <CAKJRP3RFzVsbo2ow00K3pd65UChX=+Gc-xMgKcU69mGGtWG_KQ@mail.gmail.com> |
Heh... this doesn't surprise me, since I was told by BTAC that they do not "support" LLDP-MIB on fastiron/ICX devices. We did end up getting product management involved to get our issue fixed (namely, SNMP is missing LLDP info for ports after a windows 10 device), but only in the 8.0.30 code train (which has a lot of major changes from 8.0.10). Speaking of which, is anyone running 8.0.30 on ICX switches with mac-based authentication enabled? They really want us to upgrade, but it terrifies me since it sounds like the mac-auth/802.1x support was re-written from the ground up (which could be good or bad). -- Eldon On Thu, Mar 9, 2017 at 12:36 PM, Wilbur Smith <[email protected]> wrote: > Sorry you’re having issues with our MIB support. We try to support as many > MIB OIDs as possible on as many platforms, but the reality is additional > code needs to be written for every new OID. Optics can be specifically > challenging because there’s no standard RFC based MIB to pull some types of > data from the optic. I checked and this isn’t included in RFC-1213 (MIB-II), > RFC-1775 (RMON), RFC-4133 (Entity), > > > > Different optics manufacturers will also use different standards for passing > this information; this standard also needs to also be compatible with the > SERDES & chipset vendor’s own implementation. Sometimes supporting this > isn’t as clear cut as we would like it to be and can take time & resources > to build. We’re pretty good about supporting customer RFC’s though and we’ve > added a lot of OID values to Fastiron & VDX based on customer requests, so > we may add support for your request in a future release. Disclaimer: I’m not > a Program Manager and can’t give you any insight into if/when. > > > > For VDX it does look like we support OID strings for portFault, noLight, etc > on Fiber Channel ports (see string 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.3). > Because of the way VDX thinks of Ethernet & FC ports this OID may return > data for an Ethernet optic…worth a try. > > > > Wilbur > > > > > > From: foundry-nsp [mailto:[email protected]] On Behalf Of > Youssef Bengelloun-Zahr > Sent: Monday, February 27, 2017 2:26 AM > To: [email protected] > Subject: [f-nsp] Basic SNMP MIBs missing > > > > Dear Community, > > Just wanted to share a basic / silly / simple experience I have gone through > with our favorite $VENDOR. > > We use observium as an NMS for our backbone (MLXe / CERT, FCX,VDX) and I > recently noticed lack of support for basic SNMP MIBs, in particular ones > responsible for gathering transceivers' sensors values for FCX and VDX > switchs. > > After opening cases with BTAC, I was told that it was perfectly normal (in > 2017 !?!) because those specific MIBs were not implemented by design and > that if I needed them, I should open up RFE requests... which I did with the > help of my local SE : > > PRODRFE104332: regarding VDX implementation > PRODRFE104333: regarding FCX implementation > > > It has also made its' way on Observium's facebook page : > https://fr-fr.facebook.com/observium/ > > So, if you do love your favorite $VENDOR as much as we do and consider that > your big bucks are worth having basic SNMP support in 2017, please start > harrassing your SEs in order for SNMP MIBs to be implemented. > > I hope this feedback will inspire you. > > Best regards. > > > _______________________________________________ > foundry-nsp mailing list > [email protected] > http://puck.nether.net/mailman/listinfo/foundry-nsp _______________________________________________ foundry-nsp mailing list [email protected] http://puck.nether.net/mailman/listinfo/foundry-nsp