Re: [f-nsp] Basic SNMP MIBs missing

Eldon Koyle <[email protected]>
Newsgroups gmane.network.nsp.foundry
Message-ID <CAKJRP3RFzVsbo2ow00K3pd65UChX=+Gc-xMgKcU69mGGtWG_KQ@mail.gmail.com>
Heh... this doesn't surprise me, since I was told by BTAC that they do
not "support" LLDP-MIB on fastiron/ICX devices.  We did end up getting
product management involved to get our issue fixed (namely, SNMP is
missing LLDP info for ports after a windows 10 device), but only in
the 8.0.30 code train (which has a lot of major changes from 8.0.10).

Speaking of which, is anyone running 8.0.30 on ICX switches with
mac-based authentication enabled?  They really want us to upgrade, but
it terrifies me since it sounds like the mac-auth/802.1x support was
re-written from the ground up (which could be good or bad).

-- 
Eldon

On Thu, Mar 9, 2017 at 12:36 PM, Wilbur Smith <[email protected]> wrote:
> Sorry you’re having issues with our MIB support. We try to support as many
> MIB OIDs as possible on as many platforms, but the reality is additional
> code needs to be written for every new OID. Optics can be specifically
> challenging because there’s no standard RFC based MIB to pull some types of
> data from the optic. I checked and this isn’t included in RFC-1213 (MIB-II),
> RFC-1775 (RMON),  RFC-4133 (Entity),
>
>
>
> Different optics manufacturers will also use different standards for passing
> this information; this standard also needs to also be compatible with the
> SERDES & chipset vendor’s own implementation. Sometimes supporting this
> isn’t as clear cut as we would like it to be and can take time & resources
> to build. We’re pretty good about supporting customer RFC’s though and we’ve
> added a lot of OID values to Fastiron & VDX based on customer requests, so
> we may add support for your request in a future release. Disclaimer: I’m not
> a Program Manager and can’t give you any insight into if/when.
>
>
>
> For VDX it does look like we support OID strings for portFault, noLight, etc
> on Fiber Channel ports (see string 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.3).
> Because of the way VDX thinks of Ethernet & FC ports this OID may return
> data for an Ethernet optic…worth a try.
>
>
>
> Wilbur
>
>
>
>
>
> From: foundry-nsp [mailto:[email protected]] On Behalf Of
> Youssef Bengelloun-Zahr
> Sent: Monday, February 27, 2017 2:26 AM
> To: [email protected]
> Subject: [f-nsp] Basic SNMP MIBs missing
>
>
>
> Dear Community,
>
> Just wanted to share a basic / silly / simple experience I have gone through
> with our favorite $VENDOR.
>
> We use observium as an NMS for our backbone (MLXe / CERT, FCX,VDX) and I
> recently noticed lack of support for basic SNMP MIBs, in particular ones
> responsible for gathering transceivers' sensors values for FCX and VDX
> switchs.
>
> After opening cases with BTAC, I was told that it was perfectly normal (in
> 2017 !?!) because those specific MIBs were not implemented by design and
> that if I needed them, I should open up RFE requests... which I did with the
> help of my local SE :
>
> PRODRFE104332: regarding VDX implementation
> PRODRFE104333: regarding FCX implementation
>
>
> It has also made its' way on Observium's facebook page :
> https://fr-fr.facebook.com/observium/
>
> So, if you do love your favorite $VENDOR as much as we do and consider that
> your big bucks are worth having basic SNMP support in 2017, please start
> harrassing your SEs in order for SNMP MIBs to be implemented.
>
> I hope this feedback will inspire you.
>
> Best regards.
>
>
> _______________________________________________
> foundry-nsp mailing list
> [email protected]
> http://puck.nether.net/mailman/listinfo/foundry-nsp
_______________________________________________
foundry-nsp mailing list
[email protected]
http://puck.nether.net/mailman/listinfo/foundry-nsp
lmpx.com only provides a reader for public news (NNTP) servers. It is not affiliated with the servers or forums shown here and is not responsible for the content of articles, which is written by their respective authors.