Re: [f-nsp] BR-MLX-MR2-X / BR-MLX-100GX2 modules not recognized,

Eldon Koyle <[email protected]> Wed, 15 Aug 2018 08:17:16 -0600
Newsgroups gmane.network.nsp.foundry
Message-ID <CAKJRP3Qyc2+m3w_Ezy9PPVynDv9zdr6VXtrMmFc+7ZeWGgM9+g@mail.gmail.com>
Could you include the output of 'show module'?  Are these
BR-MLX-100GX2-CFP2-X or -M cards?

Do you have any non-X cards installed or configured?  Does the management
module show up as a -X if you erase start and boot without any line cards?

-- 
Eldon


On Wed, Aug 15, 2018, 02:42 Franz Georg Köhler <[email protected]> wrote:

> On Di, Aug 14, 2018 at 05:05:01 +0000, Joseph Clark <
> [email protected]> wrote:
> > We have some BR-MLX-MR2-X and BR-MLX-100GX2-CFP2 modules that are
> > having issues.  The BR-MLX-MR2-X shows up as a BR-MLX-MR2-M in the
> > chassis even though it has the "X" sticker on it, and the 100GX2-CFP2
> > comes up as "Module in slot 7 is not enabled due to type mismatch".
> > We uploaded the code revision and rebooted but still having the same
> > results.   The 100GX2 is being recognized in the chassis but we
> > continue to get the "type mismatch" error.  Any ideas on what we can
> > try?
>
>
> Is there any configuration left from another module in that specific
> slot? In that case, it will not boot up the new module, as its type
> differs from the configuration.
>
>
> Best regards,
>
> Franz Georg Köhler
> _______________________________________________
> foundry-nsp mailing list
> [email protected]
> http://puck.nether.net/mailman/listinfo/foundry-nsp
>

_______________________________________________
foundry-nsp mailing list
[email protected]
http://puck.nether.net/mailman/listinfo/foundry-nsp